3. Specifications
3.14 Electrical connections model O-10 (T)
Available connections

Electrical connection

Angular connector DIN 175301-803 A IP 65
Angular connector DIN 175301-803 C IP 65
Circular connector M12 x 1 (4-pin)
Metri-Pack series 150
1)
Cable outlet, unshielded
Cable outlet, shielded
1) for model O-10 (T) only possible from measuring range 0 ... 60 bar
2) up to a maximum of 80 °C permitted
The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors
that have the appropriate ingress protection.
Short-circuit resistance
S + vs. 0V
Reverse polarity protection
U B vs. 0V
Overvoltage protection
DC 36 V
Insulation voltage
DC 750 V
WIKA operating instructions pressure transmitter model O-10
Ingress
protection
IP 67
IP 67
IP 67
2)
IP 67
Wire cross-
Cable
section
diameter
-
-
-
-
-
-
-
-
0.14 mm
3.4 mm
2
0.14 mm
4.3 mm
2
GB
Cable
lengths
-
-
-
-
2 m , 5 m
2 m , 5 m
19