3. Specifications
Service life
10 million load cycles
Temperatures
Permissible temperature range
Standard
Ambient
0 ... +80 °C
Medium
0 ... +80 °C
Storage
-20 ... +80 °C
3.5 Reference conditions (per IEC 61298-1)
Temperature:
Atmospheric pressure: 860 ... 1,060 mbar
Humidity:
Power supply:
Mounting position:

3.7 Electrical connections

Specifications
Designation
Angular connector DIN 175301-803 A
with mating connector
with solid laid cable
Angular connector DIN 175301-803 C
with mating connector
with solid laid cable
WIKA operating instructions pressure transmitter model A-10
Option
-30 ... +100 °C
-30 ... +100 °C
-30 ... +100 °C
15 ... 25 °C
45 ... 75 % relative
DC 24 V
as required
Ingress
protection
IP 65
IP 65
IP 65
IP 65
Wire
Cable Ø
cross-section
2
up to max. 1.5 mm
6 ... 8 mm
2
3 x 0.75 mm
6 mm
2
up to max. 0.75 mm
4.5 ... 6 mm -
2
4 x 0.75 mm
5.9 mm
GB
Cable
material
-
PUR
PUR