10

Technical data

10.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
10.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
10)
MB004T1 - 11068581
9...30 VDC
5 VDC ± 5 % (TTL)
≤100 mA
300...5000 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz, ≤300 kHz option
A, B, R + inverted
Error output (option EMS)
HTL-P (power linedriver), TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E256710
ø97 mm
ø12...16 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
≤400 N axial, ≤500 N radial
IP56
≤10000 rpm (mechanical)
6 Ncm
160 gcm
Housing: aluminium die-cast, shaft: stainless steel
-30...+100 °C
-25...+100 °C (>3072 pulses per revolution)
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 17 g, 10-2000 Hz
IEC 60068-2-27
Shock 275 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
Flange connector M23, 12-pin (option G: 2x)
800 g, 1.6 kg (option G)
Baumer_HOG9-HOG9G-T1_II_DE-EN (18A2)
(HTL-P, TTL - version R)
10)
2
10
Technical data
30

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hog 9gHog9

Inhaltsverzeichnis