Herunterladen Inhalt Inhalt Diese Seite drucken

Description Of The Hood; Operation - Elica LI3FSC Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Description of the hood

Fig. 1
1.
Control panel
2.
Grease filter
3.
Grease filter release handle
4.
Extractable lights drawer
Note: The extractable lights drawer is normally closed.
Pressing the switching on the lights command, the
drawer opens, making it possible to illuminate the
cooking top.
Attention! Do not pull or push the extractable lights
drawer to not damage it.
5.
Vapour catcher
6.
Air outlet
7.
Telescopic chimney (*)
8.
Remote Control (*)
The steam screen must always be left closed and opened only
for maintenance (e.g. cleaning or changing filters).

Operation

Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
It is sufficient to touch the keys lightly to select the
functions of the hood.
Key
Function
Light ON: lights on, wait for the extractable
lights drawer to open.
Light OFF: lights off, wait for the extractable
lights drawer to close.
INTENSIVE suction power ON timed at 5
minutes: the hood sets this power and at the
end of the 5 minutes returns to the previous
setting.
Anticipated INTENSIVE suction power
OFF:
Press the same key again to return
beforehand to the previous setting.
Suction power HIGH
Suction power MEDIUM
Carbon filter saturation indicator.
When this flashes it indicates the need to
wash or replace the carbon filter.
Note: the key might flash because the
"Timed turning off of the hood" has been
selected (see below).
Activation/Deactivation signal of carbon
filter saturation.
This signal is normally deactivated. To
activate it:
Press the motor OFF key for more than 3
seconds. The motor OFF key turns off.
Press keys 1 and 2 at the same time. At first
only key 1 flashes, then both keys 1 and 2
flash to indicate activation. Repeat the
operation to deactivate the signal. First keys
1 and 2 will flash and then only key 1, to
indicate deactivation. .
Low suction power
Signals carbon filter saturation.
When it flashes, it indicates the need to wash
or replace the fats filter.
Note: the key might flash because the
"Timed turning off of the hood" has been
selected (see below).
Motor OFF (stand by)
Reset filters signal
After having carried out maintenance of
the filters, press the key for ore than 3
seconds, Flashing led 1 (fats filter) or 2
(carbon filter) stop flashing.
Exclusion of the Electronics – Press
the key for more than 3 seconds – the
key turns off – all the keys, except the
light key, are deactivated.
This function can be useful during the
operation of cleaning the product.
Just repeat the operation to reinstate the
electronics
Note: the light key remains active.
Timed turning off of the hood:
After having selected any one of the available suction
powers, turning off (stand by) the hood can be set
pressing the same key for more than 2 seconds, within a
time defined as follows:
Intensive suction power: 5 minutes
HIGH suction power: 10 minutes
MEDIUM suction power: 15 minutes
LOW suction power: 20 minutes.
The power key and the motor OFF key (stand by)
begin to flash.
In the case of possible functioning anomalies, before
calling the assistance service, disconnect the electricity
supply equipment for at least 5 seconds, take the plug out
and then connect it again. If the functioning anomaly
perseveres, call the assistance service.
12