Steam screen
The steam screen must always be left closed and
opened only for maintenance (e.g. cleaning or changing
filters).

Grease filter

This must be cleaned once a month (or when the filter
saturation indication system – if envisaged on the model in
possession – indicates this necessity) using non aggressive
detergents, either by hand or in the dishwasher, which must
be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
Open the steam screen.
Pull the handle downwards and extract the filter. Fig. 2

Charcoal filter (filter version only)

Fig. 3
It absorbs unpleasant odours caused by cooking.
The charcoal filter can be washed once every two months (or
when the filter saturation indication system – if envisaged on
the model in possession – indicates this necessity) using hot
water and a suitable detergent, or in a dishwasher at 65°C (if
the dishwasher is used, select the full cycle function and leave
dishes out).
Eliminate excess water without damaging the filter, then put it
in the oven for 10 minutes at 100° C to dry completely.
Replace the mattress every 3 years and when the cloth is
damaged.
Montage
Open the steam screen and remove the grease filter.
Install the carbon filter on the back of the grease filter and
fix with two rods.
Attention! The rods are included in the carbon filter
packing and not on the hood.
To dismantle the filter act in the reverse manner.

Replacing lamps

Fig. 4
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs ensure they are
cooled down.
Use a small screwdriver as a lever on the borders of the
lamp in order to remove the lightbulb.
Slide out the lightbulb to be replaced and replace with a
new 12V 20W MAX 30° Ø35 12V GU4.
Carry out the replacement and mount the new lightbulb
by following instructions in the reverse.
If the lights do not work, make sure that the lamps are fitted
properly into their housings before you call for technical
assistance.