Type of Error
a. Data Input
Input Error
Code Error
b. System
Clock Error
Pressure Sensor Defective
Heating Sensor Defective
Temperature Sensor
Defective
Printer not Ready
c. Welding Process
Temperature low
Temperature high
Error Changeover
Ambient Temper. high
Ambient Temperature low
Error Drag Pressure
Error Build-up Pressure
Error Heat Soak Pressure
Error Joining Pressure
Cooling Stopped
Power Supply Failure
Error Plate Temperature
5

Printing/Downloading Welding Reports

The product is equipped with two USB interfaces for data transfer.
USB A Interface
for connecting USB printers and USB mass storage media (such as
a USB stick)
USB B Interface
for connecting the welding machine directly to a PC on which the
welding data management software DataWork is installed
Both interfaces comply with the USB version 1.1 specification (i.e.,
maximum data rate of 12 megabits per second).
Version May 2011
Error while entering data with the cursor keys.
Error while reading data from a bar code.
The internal clock of the machine is defective; re-set the clock in the
Configuration Menu.
The sensor indicated on the display (hydraulic pressure, heating
element temperature, ambient temperature) is defective; where
possible, check the connections/plug; have the machine inspected by
an authorized service shop if needed.
The printer or PC connected to the machine is not ready (no
communication or faulty cable).
Heating element temperature will be increased automatically.
Heating element temperature will be reduced automatically.
It took too long to retract the heating plate and bring the pipes to
joining; welding will have to be repeated.
Outside temperature outside the range from – 5°C to + 50°C.
Outside temperature outside the range from – 5°C to + 50°C.
Impossible to determine the drag pressure; maybe pipes will have to
be clamped once again; or the pressure is below 1 bar, which is not
feasible for technical reasons.
Build-up pressure too high or too low and was not re-adjusted in
time.
Heat-soaking pressure too high and was not re-adjusted in time.
Joining pressure too high or too low and was not re-adjusted in
time.
Operator has stopped the cooling time by pressing the STOP/REST
key.
In the course of the last welding a power supply failure occurred;
welding has to be repeated.
This error occurs only when the machine is switched on after the
welding operation during which the supply failure happened. It
then has to be reacted to by pressing the STOP/RESET key.
Heating element temperature is out of tolerance; impossible to
re-adjust the temperature; maybe the ambient temperature was too
low.
HÜRNER WeldControl 500-R User's Manual
Description
21
EN
Inhaltsverzeichnis
loading