Herunterladen Inhalt Inhalt Diese Seite drucken

MAHLE ArcticPro 200yf Originalbetriebsanleitung Seite 55

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
en
56 | ArcticPro 200yf | Troubleshooting
Error code Messages
9102
FACTORY SETTING:
Not completed.
9201
SYSTEM ERROR:
No USB detected.
9300
SELF-TEST UNSUCCESSFUL:
View detail.
9600
PRINTER:
No paper in printer.
A101
INTERNAL BOTTLE FILL:
Time elapsed.
A103
INTERNAL BOTTLE FILL:
Refrigerant cylinder full.
A104
INTERNAL BOTTLE FILL:
High pressure shutdown.
A105
INTERNAL BOTTLE FILL:
Low pressure.
A202
SHORT FLUSHING:
Service timeout.
A203
SHORT FLUSHING:
Insufficient R1234yf quantity.
A204
SHORT FLUSHING:
Leak detected.
A205
SHORT FLUSHING:
High pressure shutdown.
A206
SHORT FLUSHING:
High pressure in vehicle.
A208
SHORT FLUSHING:
Refrigerant cylinder full.
A209
SHORT FLUSHING:
Charging unsuccessful.
A302
EXTENDED FLUSHING:
Service timeout.
A303
EXTENDED FLUSHING:
Insufficient R1234yf quantity.
A304
EXTENDED FLUSHING:
Leak detected.
A305
EXTENDED FLUSHING:
Deactivate high pressure.
A306
EXTENDED FLUSHING:
High pressure in vehicle.
A307
EXTENDED FLUSHING:
Used oil bottle full.
A308
EXTENDED FLUSHING:
Refrigerant cylinder full.
A309
EXTENDED FLUSHING:
Charging unsuccessful.
A701
CALIBRATION CHECK:
Weight not attached.
A702
CALIBRATION CHECK:
Failed.
© MAHLE
Action
• Complete all vehicle information.
• Check whether USB stick is connected to USB connection.
• View details.
• Take corrective action to rectify error.
• Check for paper in printer.
• Check for clogging of ArcticPro 200yf.
• Weight limit reached. Reduce quantity of refrigerant in internal
refrigerant cylinder.
• Check scales.
• Check whether the valves on the internal refrigerant cylinder are open.
• Check for clogging of service hoses.
• Check whether the valves on the external refrigerant cylinder are open.
• Check for clogging of service hoses.
• Check for clogging of ArcticPro 200yf.
• Charge the internal refrigerant cylinder.
• Repair vehicle air conditioning system or part being flushed.
• Check low-pressure valve at internal refrigerant cylinder.
• Check for clogging of service hoses.
• Perform recovery if pressure is above 0.6 bar.
• Generate vacuum if pressure is 0.6 bar.
• Weight limit reached.
• Reduce quantity of refrigerant in internal refrigerant cylinder.
• Check scales
• Check for clogging of service hoses.
• Check for clogging of ArcticPro 200yf.
• Charge the internal refrigerant cylinder.
• Check for leak at part just being flushed.
• Check for clogging of ArcticPro 200yf.
• Pressure is above 0.6 bar during extraction.
• Perform recovery.
• Empty used oil bottle.
• Reset scales.
• Weight limit reached. Reduce quantity of refrigerant in internal
refrigerant cylinder.
• Check scales.
• Replace scales.
• Check for clogging of service hoses.
• Attach calibrating weight.
• Perform calibration again.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Verwandte Produkte für MAHLE ArcticPro 200yf

Inhaltsverzeichnis