Safety precautions
When connected to the power supply the transformer generates heat, even when the device is
switched off. Make sure that this heat can be emitted freely and that it does not affect any heat-
sensitive objects, otherwise these could be turned into a potential source of danger.
The device should only be used if it can be operated safely. When it is assembled on scaffolding
the device should only be mounted on the inside of the scaffolding in the upper section of the
backrest. After it has been mounted in the upper section the device is to be secured and preven-
ted from falling by securing the locking bolt on the scaffolding mount (rear side of the device).
If it is not possible to secure the device or the lower section of the backrest is missing, the device
should not be operated! After installing the device at the designated location make sure that it
is stable.
If an installed device is left unattended, protect it against external influences and unauthorised
use. Remove the mains plug. The operator of the device is responsible for making sure that any
sources of danger and potential tripping hazards in the vicinity of the device are eliminated (e.g.
unsecured power cables, packaging, etc.).
Troubleshooting
A regular and careful cleaning and maintenance schedule is required to ensure trouble-free operation. The transformer
should be disconnected from the socket during troubleshooting measures. Remove the mains plug!
If the wire does not heat up, check the 230 V power supply. Check or replace the transformer fuse (art. no. 57 00 04). If
this does not resolve the malfunction, contact the STORCH service department or one of the STORCH service centres in
your area. Do not attempt to repair the transformer yourself and do not replace it with a type not approved by STORCH.
Other malfunctions that require the device to be repaired may only be performed by qualified STORCH personnel or one
of the authorised STORCH service centres.

Personnel qualification

The device should only be assembled, commissioned, operated, maintained and cleaned by those persons who are autho-
rised, qualified and trained to do so.
Spare parts, consumables
All of the device components are available from STORCH and its distribution partners. We recommend that you keep
sufficient quantities of the original cutting wire (d = 0.7 mm) art. no. 57 00 46 (ProCut basic) / 57 00 48 (ProCut basic
128) and fine wire fuses 8A art. no. 57 00 04 in stock.