6. Troubleshooting

Before you ask for repair service, check the following points:
State of Machine
Remote Controller
"
" display is not lit up.
No display appears even
It does not run.
when the [ON/OFF] but-
ton is pressed.
Air flows out but it does
The liquid crystal display
not cool enough or
shows that it is in the
heat enough.
state of operation.
The liquid crystal display
Cool air or warm air
shows that it is in opera-
does not come out.
tion.
The "CHECK" and check
It runs briefly, but soon
code flashes on the liquid
stops.
crystal display.
The sound of the
exhaust and rotation of
All lights are out except
the motor can still be
the powered display of
heard after stop of run-
"
".
ning.
The sound of the
exhaust and the rota-
All lights are out except
tion of the motor can
the powered display of
be heard intermittently
"
".
after stop of running.
Warm air comes out
The liquid crystal display
intermittently when the
shows that it is in the
thermostat is OFF or
state of operation.
during fan operation.
• If operation stops due to a power failure, the [restart-preventing circuit at power failure] operates and disables unit operation even after power restoration. In this case, press
the [ON/OFF] button again and start operation.
If malfunctions persist after you have checked the above, turn the power supply OFF and contact your dealer with information about the product name, the nature of the
malfunction, etc. If the display of "[CHECK]" and (4 digit) check code flashes, tell the dealer contents of the display (check code). Never attempt to repair by yourself.
The following symptoms are not air conditioner failures:
• The air blown out from the air conditioner can sometimes give off odors. This is due to cigarette smoke contained in the air of the room, the smell of cosmetics, the walls, fur-
niture, etc., absorbed in the air conditioner.
• The air conditioner sometimes snaps or clicks at the beginning or end of cooling/heating operation. This is the sound of friction on the front panel and other sections due to
expansion and contraction caused by temperature change. This is normal.
• The fan speed changes in spite of not changing the setting. Not to blow out cold air at the beginning of heating operation, the air conditioner automatically adjusts the fan
speed gradually from lower to the set speed. It also adjust its fan speed to protect the fan motor when return air temperature or fan speed excessively rises.

7. Installation, transferring works, and checking

Regarding place for installation
Consult with your dealer for details on installation and transferring the installation.
Caution:
Never install the air conditioner where there is a risk of leakage of flammable
gas.
If gas leaks and accumulates around the unit, fire can result.
Never install the air conditioner at the following place:
• where there is a lot of machine oil
• near the ocean and beach areas where there is salt air.
• where humidity is high
• where there are hot springs nearby
• where there is sulphurous gas
• where there is a high-frequency processing machinery (a high-frequency welder,
etc.)
• where acid solution is frequently used
• where special sprays are frequently used
• Install the indoor unit horizontally. Otherwise, water leakage can result.
• Take sufficient measures against noise when installing the air conditioners at hos-
pitals or communication-related businesses.
If the air conditioner is used in any of the above-mentioned environments, frequent
operational failure can be expected. It is advisable to avoid these types of installation
sites.
For further details, consult with your dealer.
6
Cause
Power failure
The power supply is turned OFF.
The fuse in the power supply is gone.
The earth leakage breaker is gone.
Improper temperature adjustment
The filter is filled with dust and dirt.
There are some obstacles at the air inlet and outlet of the
indoor and outdoor units.
Windows and doors are open.
The restart-preventing circuit is in operation for 3 minutes.
Indoor unit operation was restarted during the heating and
defrosting operation.
There are some obstacles at the air inlet and outlet of the
indoor and outdoor units.
The filter is filled with dust and dirt.
When other indoor units are engaged in cooling operation,
the machine stops after running a drain-up mechanism for
3 minutes when air-cooling operation is stopped.
When other indoor units are engaged in cooling operation,
drained water is brought in. If the drain water is collected,
the drain-up mechanism initiates a draining operation.
When other indoor units are engaged in heating opera-
tion, the control valves are opened and closed from time
to time to maintain the stability of the system.
Regarding electrical work
• The electrical work must be undertaken by a person who is qualified as an
• Never connect the grounding wire to a water pipe, arrester, or telephone
• In some types of installation sites, the installation of an earth leakage
Regarding transfer of installation
• When removing and reinstalling the air conditioner when you enlarge your home,
When moving or reinstalling the air conditioner, consult with your dealer. De-
fective installation can result in electric shock, fire, etc.
Press the [ON/OFF] button after power restoration.
Turn the power supply ON.
Replace fuse.
Put in the earth leakage breaker.
After checking the set temperature and inlet temperature
on the liquid crystal display, operate the adjustment button.
Clean up the filter.
(Refer to [Caring for the machine].)
Remove.
Close.
Wait for a while.
(To protect the compressor, a 3-minute restart-preventing
circuit is built into the indoor unit. Therefore, there are occa-
sions sometimes when the compressor does not start run-
ning immediately. There are cases when it does not run for
as long as 3 minutes.)
Wait for a while.
(Heating operation starts after ending defrosting operation.)
Rerun after removal
Rerun after cleaning the filter. (Refer to [Caring for the
machine].)
Wait for 3 minutes.
It soon stops. (If the noise occurs more than 2-3 times in an
hour, ask for repair service.)
It soon stops. (If the room temperature rises uncomfortably
high in a small room, stop operation.)
Caution:
electrical engineer according to the [technical standard respecting electri-
cal installation], [internal wiring rules], and the installation instruction man-
ual with the absolute use of exclusive circuits. The use of other products
with the power source can result in burnt-out beakers and fuses.
grounding wire. For details, consult with your dealer.
breaker is mandatory. For details, consult with your dealer.
remodel, or move, consult with your dealer in advance to ascertain the cost of the
professional engineering work required for transferring the installation.