Troubleshooting

Troubleshooting by users
Problem
No hot water.
Although the hot water tap is fully
open, the heater does not switch on.
Troubleshooting by experts
Problem
The „Red" stage of the heater does not
switch on.
Although the hot water tap is fully
open, the flow controller does not ac-
tivate.
The heating system does not switch on/
No hot water.
Declaration of conformity
Safety
Check the fuses.
Check if any fittings or shower head are affected by the build-up of limescale or dirt.
See also „Troubleshooting by users".
Cause
No electricity.
The required minimum flow to activate
the heater is not reached. Dirt or limes-
cale has built up in the aerators of the
taps or in the shower head.
Cause
The pressure on the cold water pipe is
too low.
Fouling
The required minimum flow to activate
the heater is not reached.
No electricity.
Heater faulty
Quantex Group B.V. hereby declares that the Thermoflow instantaneous water heater
complies with the directives and standards.
Low Voltage Directive 2006/95/EC
Electromagnetic Compatibility Directive 2004/108/EC
CE Marking Directive 93/68/EC
And also comply with the provisions of the following European Standards:
EN 62233:2008
EN 60335-1:2002 + A1:2004 + A11:2004 + A12:2006 + A2:2006 + C1:2006 + A1:2004/
C11:2007 + A13:2008
EN 60335-2-35:2002 +A1:2007
Gildestraat 13, 6883 DB Velp, The Netherlands, 16.September 2011
Children should be supervised to ensure that they do not play with the appliance.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
remedy
Check the fuses in the consumer unit.
Clean or descale.
remedy
Descale or clean the shower head and
aerators.
Clean the cold water strainer.
Clean the cold water strainer.
Check fuse (consumer unit).
Measure the resistance of the heater
and replace it if necessary.