Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Dimensions, Weight, Ambient; Supply Voltage; Connection - Balluff BTL5-H1_ _-M_ _ _ _-A-S94 serie Betriebsanleitung

Vorschau ausblenden Andere Handbücher für BTL5-H1_ _-M_ _ _ _-A-S94 serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL5-H1_ _-M_ _ _ _-A/B/Z-S94
Micropulse Linear Transducer - Rod Style
8

Technical Data

Typical values at DC 24 V and room temperature. Ready for operation at once, full accuracy after warm-up. With
magnet BTL-P-1013-4R, BTL-P-1013-4S or BTL-P-1012-4R:
Resolution:
Position
> 5 µm
settable over SDO
in steps of 5 µm
Speed
> 0.1 mm/s
settable over SDO
in steps of 0.1 mm/s
Meas. rate f
= 1kHz
standard
Non-linearity
± 30 µm
Hysteresis
< 1 LSB
Repeatability
< 2 LSB
(resolution + hysteresis)
Temperature coefficient
(6 µm + 5 ppm * nominal length)/K
Shock
100 g/6 ms
1
per IEC 60068-2-27
Continuous shock 100 g/2 ms
1
per IEC 60068-2-29
Vibration
12 g, 10 to 2000 Hz
per IEC 60068-2-6
1
(take care to avoid inherent reso-
nances of protective tube)
Pressure
up to 600 bar
when installed in a
hydraulic cylinder
1
Individual specifications as per
Balluff factory standard
8.1
Dimensions, weight,
ambient
Nominal length < 4000 mm
➥ ➥ ➥ ➥ ➥ Fig. 3-2
Dimensions
Weight
approx. 2 kg/m
Housing
anodized
aluminum
Pressure tube
Stainless steel 1.4571
diameter
10.2 mm
wall thickness
2 mm
e-modulus
approx. 200 kN/mm
Mounting threads
M18×1.5 or 3/4"-16UNF
Operating temp. –40 °C to +85 °C
Humidity < 90 %, non-dewing
Protection rating
per IEC 60529
IP 67
with connector attached
8.2
Supply voltage (external)
Voltage regulated
BTL5-_ 1...
DC 20 to 28 V
Ripple
24 V + 2 V
Current draw
< 100 mA
Inrush
< 3 A/0.5 ms
Polarity reverse protection built-in
Overvoltage protection
Transzorb protection diodes
Isolation voltage
GND to housing
500 V DC
8.3

Connection

➥ ➥ ➥ ➥ ➥ Fig. 4-2
Cable:
twisted-pair, shielded, Ø 6 to 8
mm,
max. length 2500 m,
stubs max. 0.3 m
8.4

Signals to Controller

CAN_Low, CAN_High, CAN_GND
corresponding to CiA DS 301
Important notice:
Status changes of each of the
4 cams will be transmitted as
emergency objects with the high-
est priority after < 0.5 ms. Hence,
these transducers are specially
suited for time-critical control
tasks.
8.5

Included in shipment

➥ ➥ ➥ ➥ ➥ Fig. 3-2
Transducer
2
8.6

Magnets

(please order separately)
Magnets BTL-P-1013-4R,
BTL-P-1013-4S, BTL-P-1012-4R
pp
Dimensions
Weight
Housing
Operating temp. –40 °C to +85 °C
Included:
8 mm spacer
Material
Magnet BTL5-P-4500-1
(Electromagnet)
Weight
Housing
Operating temp. –40 °C to +60 °C
8.7
Accessories (optional)
Connector (female)
Connector (male)
Close-off cap
Connection cable
Transparent cover
8.8

Mounting nuts

(order separately)
Mounting nuts M18x1.5
BTL-A-FK01-E-M18X1.5
Mounting nuts 3/4"-16UNF
BTL-A-FK01-E-3/4"-16UNF
english
➥ ➥ ➥ ➥ ➥ Fig. 3-4
approx. 10 g
anodized
aluminum
POM
(polyoxymethylene)
approx. 80 g
plastic
➥ ➥ ➥ ➥ ➥ Fig. 4-3
➥ ➥ ➥ ➥ ➥ Fig. 4-4
➥ ➥ ➥ ➥ ➥ Fig. 4-5
➥ ➥ ➥ ➥ ➥ Fig. 4-6
➥ ➥ ➥ ➥ ➥ Fig. 4-7
9

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Btl5-h1_ _-m_ _ _ _-z-s94 serie