BTL5-T1_ _-M_ _ _ _-A/B/Y/Z-S103
Micropulse Linear Transducer - Rod Style
9

Technical Data

Typical values at DC 24 V, room temperature and BTL with nominal length of 500 mm. Ready for operation at once,
full accuracy after warm-up. With magnet BTL-P-1013-4R, BTL-P-1013-4S or BTL-P-1012-4R:
Resolution, selectable
in steps of
5 µm
Velocity, selectable
in steps of
0.1 mm/s
Sampling rate f
= 1 kHz
Standard
Non-linearity
± 30 µm
Hysteresis
< 1 LSB
Repeatability
< 2 LSB
Temperature coefficient
< (6 µm + 5 ppm * nominal length)/K
Shock loading
100 g/6 ms
1
per EN 60068-2-27
Continuous shock 100 g/2 ms
1
per EN 60068-2-29
Vibration
12 g, 10 to 2000 Hz
1
per EN 60068-2-6
(take care to avoid inherent reso-
nances of protective tube)
Pressure
up to 600 bar
when installed in a hydraulic cylin-
der
1
Individual specifications as per Balluff
factory standard
9.1
Dimensions, weights,
ambient conditions
Nominal length
< 4000 mm
➥ ➥ ➥ ➥ ➥ Fig. 3-1
Dimensions
Weight
approx. 2 kg/m
Housing
anodized aluminum
Pressure tube stainless steel 1.4571
diameter
10.2 mm
wall thickness 2 mm
E-modulus
ca. 200 kN/mm
Mounting threads
M18 × 1.5 or 3/4"-16UNF
Operating temp.
–40 °C to +85 °C
Humidity < 90%, non-condensing
Protection class per IEC 60529
IP 67 when closed up
The following patents have been
granted in connection with this
product:
US Patent 5 923 164
Apparatus and Method for Auto-
matically Tuning the Gain of an
Amplifier
9.2

Supply voltage (external)

Regulated supply voltage
BTL5-T1...
Ripple
2
Current draw
Inrush
Polarity reversal protection built-in
Overvoltage protection
Transzorb diodes
Dielectric strength
GND to housing 500 V DC
2
depending on load on VP (repeater,
bus terminator)
9.3

Control signals

RxD/TxD-N, RxD/TxD-P, Data GND
per EN 50170
9.4
Connection to the
processor
Cable
Twisted-pair, shielded.
Max. fieldbus length 1200 m
2
The CE Mark verifies
that our products meet
the requirements of
EU Directive
2004/108/EC (EMC Directive)
and the EMC Law. Testing in our
EMC Laboratory, which is accred-
ited by DATech for Testing Elec-
tromagnetic Compatibility, has
confirmed that Balluff products
meet the EMC requirements of
the following Generic Standards:
EN 61000-6-1 (noise immunity)
EN 61000-6-2 (noise immunity)
EN 61000-6-4 (emission)
and the following product standard:
EN 61326-2-3
DC 20 to 28 V
< 0.5 V
ss
< 130 mA
< 3 A/0.5 ms
➥ ➥ ➥ ➥ ➥ Fig. 4-2
File No.
E227256
Emission tests:
RF Emission
EN 55016-2-3 (industrial area)
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Electromagnetic fields (RFI)
EN 61000-4-3
Fast transients (Burst)
EN 61000-4-4
Surge
EN 61000-4-5
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Magnetic fields
EN 61000-4-8
Severity level 3
Severity level 3
Severity level 3
Severity level 2
Severity level 3
Severity level 4
11
english