LOW
VAC

SPECIFICATIONS

• Pressure Display: PSI, INHg, Bar, MPa, Kg/cm 2
• Deep Vacuum Display: Micron, mBar, KPa, Pa, Torr, mTorr, mmHg
• Temperature Display: °F or °C
• Sensing Resolution: 1 psi (.07 Bar, .007 MPa, .07 Kg/cm 2 )
• Sensing Accuracy: ±1 psi or 1% of reading (whichever is greater)
• Working Pressure: 0 to 750 psi (52 Bar, 5 MPa, 52 Kg/cm 2 ) (does not display 0-5 psi)
• Proof Pressure: 1000 psi (70 Bar, 7 MPa, 70 Kg/cm 2 )
(Tolerable pressure without internal damage)
• Refrigerant Temperature Range: -40 to 200°F (-40 to 93°C)
• Operating Temperature: 32 to 122°F (0 to 45°C)
• Temperature Accuracy: ±1˚F (±0.5˚C) between 32 to 160˚F (0 to 71˚C)
• Storage Temperature: 10 to 120˚F (-12 to 49˚C)
• Connections: 1/4" M-Flare and 3/8" M-FL (vacuum hose connection)
• Power: 9V DC battery with optional AC/DC adapter
• Battery Life: 30-36 hours pressure and temperature mode only (continuous use)
25-30 hours vacuum and backlight mode (continuous use)
• Auto-Off: 15 min. with disabling capability
WARNING!!
• Wear Safety Glasses / Wear Gloves
• Keep the manifold in a dry place. Do not allow moisture to enter the unit.
• Do not vent refrigerant into the atmosphere.
• If eyes come in contact with refrigerant, immediately flush with plenty of water.
Seek medical attention immediately.
• Do not set manifold on top of an A/C system. This will result in incorrect temperature probe
readings.
• STATIC DISCHARGE: Climates in some parts of the world are conducive to creating static
electric build up (ESD). Your digital manifold has been designed to eliminate the damaging
effects of ESD. In some extreme cases, ESD will be apparent on your digital manifold by a
lack of response or an inability to turn off the unit. In the rare case that this occurs, simply
disconnect the battery, wait 1 minute and reconnect the battery. The digital manifold will
"reboot" itself and operate normally once the unit is turned on.
• The display will show zero (0) whenever the measurement falls below the following
readings: 3 PSI, 0.2 Kg/cm, 0.2 BAR, 0.02 mPA or 6 in-Hg
• The digital manifold is normally shipped with vacuum and temperature sensors that are
calibrated with the companion manifold. In the event the other sensors are provided by
another source, please contact Mastercool Inc. for calibration instructions.

BATTERY CARE

When the battery is connected to the unit but not in use it will last six months.
NOTE: In order to prolong the life of the 9V battery;
a.) keep auto-off function enabled
b.) if pressure, temperature or deep vacuum is being used for an extended period of time turn the
unit off and turn back on again when reading is required. (Allow 30-45 seconds for the correct
reading to appear.)

BATTERY INSTALLATION

Remove the battery compartment cover. Make
sure to place the battery into the compartment
with the correct polarity. Replace battery cover.

KEYPAD FUNCTIONS

POWER
2
INSTRUCTION MANUAL
4-WAY BALL VALVE Digital Manifold
HIGH
REF
Turns the unit on and off
www.mastercool.com

SPECIAL FEATURES

• Low battery indicator
• Displays 63 refrigerants
• Displays corresponding saturation, dew or
bubble point temperature for current pressure
• Displays sensor/thermocouple temperature,
superheat/subcool temperature and deep
vacuum when connected
• Includes back-lit display for easy reading in
darker areas
• 9V DC battery with optional AC/DC adapter
• Auto-Off with disabling capability
• Record & store up to 24 hours of data
• Data Logger Software Application
• 4 Way Aluminum block with ball valve design
includes 3/8" bore through block for increased
flow
BATTERY COMPARTMENT