Technical Data

Dimensions in mm:
Mains Voltage:
Power Consumption:
Protection Class:
Fuse:
Temperature Regulation:
Precision:
Flow Rate:
Compressed Air:
Compressed Air Connection:

3. Commissioning

Place the soldering tool in the holder. Insert compressed
air hose with 6 mm outer diameter in the quick action
coupling (12). Provide supply of compressed air with
400 kPa (58 psi) dry, oil-free compressed air or nitrogen
(N2).
Warning: When using nitrogen, attention must be paid
to satisfactory room ventilation.
Plug the electrical lead from the soldering tool in the 7
pole socket (7) on the front panel and lock. Connect the
compressed air hose to the compressed air connection
nipple (8). Check that the mains voltage matches that on
the rating plate and that the mains switch (1) is in the off
position. If the mains voltage is correct, plug the control
unit into the mains.
Warning: Do not direct hot air soldering tools at people
or inflammable objects.
Switch on the unit at the mains switch (1). When the unit
is switched on, a self-test is performed during which all
the indicators (2) are illuminated. The temperature set
(required value) and the temperature scale (°C/°F) are
then briefly displayed. The electronics then switch auto-
matically to the display of the actual value. The red dot
(5) on the display (2) illuminates. This dot serves as an
optical regulation monitor. Continuous illumination
means that the system is heating up. Flashing indicates
that the operating temperature has been reached.
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
166 x 134 x 101 (L x B x H)
230 V / 50 Hz (120 V / 60 Hz)
105 W
1 (Control Unit) and 3 (Soldering Tool)
230 V: T 630 mA (120 V: T 1,0 A)
°C Version
Hot Air 50°C - 550°C
Soldering Iron 50°C - 450°C
°F Version
Hot Air 122°F - 999°F
Soldering Iron 122°F - 842°F
Hot Air ± 30°C (± 54°F)
Soldering Iron ± 9°C (± 17°F)
Approx. 0 - 10 l/min
Inlet pressure 400 kPa (58 psi), oil-free, dry compressed air or nitrogen (N2)
Compressed air hose of 6 mm (0.24") diameter
Setting the temperature
The digital display (2) shows the actual value temperatu-
re. By pressing the UP or DOWN key (3, 4) the digital dis-
play (2) switches to the setpoint. The setpoint can be
changed by tapping or by firmly pressing the UP or
DOWN button (3, 4) in the desired direction. Pressing the
button will change the setpoint quickly. The digital dis-
play (2) returns automatically to the actual value appro-
ximately 2 seconds after releasing the button.
Adjusting the Air Flow Rate
The air flow rate required can be adjusted at the flow
control valve (9). Turning the control valve (9) to the left
increases the flow rate. Air is fed to the hot air soldering
tool as long as the finger operated switch is held down.
Standard setback:
Setting back the set temperature to 150°C. The setback
time, which follows the switching of the soldering stati-
on to standby mode, is 20 minutes. After three setback
times (60 minutes) the "Auto-off" function is activated.
The soldering tool is switched off (blinking line on the
display).
Setting: When switching on, hold the "UP" key (3) until
ON or OFF appears in the display. The setting is saved
when the "UP" button is released. Repeat this step to
change.