5.1 Measured values that are available at the bus interface, depending on the application

Table 1:
Sym- Meaning
bols
U
Input voltage
U12
Phase-to-phase voltage
L1 – L2
U23
Phase-to-phase voltage
L2 – L3
U31
Phase-to-phase voltage
L3 – L1
U1N Phase-to-neutral voltage
L1– N
U2N Phase-to-neutral voltage
L2 – N
U3N Phase-to-neutral voltage
L3 – N
UM
Average value of the
voltages
I
Input current
I1
AC current L1
I2
AC current L2
I3
AC current L3
IM
Average value of the
currents
IMS
Average value of the currents
and sign of the active power
IB
RMS value of the current
with wire setting range
(bimetal measuring function)
IB1
RMS value of the current
with wire setting range
(bimetal measuring function),
phase 1
IB2
RMS value of the current
with wire setting range
(bimetal measuring function),
phase 2
IB3
RMS value of the current
with wire setting range
(bimetal measuring function),
phase 3
BS
Slave pointer function for
the measurement of the
RMS value IB
BS1
Slave pointer function for
the measurement of the
RMS value IB, phase 1
BS2
Slave pointer function for
the measurement of the
RMS value IB, phase 2
BS3
Slave pointer function for
the measurement of the
RMS value IB, phase 3
Sym- Meaning
Application
bole
(see Table 2)
A11
A34
A24 /
...
A44
A16
F
––
––
––
P
P1
––
P2
––
P3
––
––
PF
––
––
PF1
––
––
PF2
––
––
PF3
––
––
––
Q
––
Q1
––
––
Q2
––
Q3
––
––
S
S1
––
S2
S3
––
LF
LF1
LF2
––
LF3
QF
––
––
QF1
QF2
––
QF3
––
EA
EB
EC
––
ED
Where c.t's and/or v.t's are used for measurement, the values
are referred to the primaries of the transformers.
Frequency of the input
variable
Active power of the system
Active power phase 1
(phase-to-neutral L1 – N)
Active power phase 2
(phase-to-neutral L2 – N)
Active power phase 3
(phase-to-neutral L3 – N)
Active power factor
cosϕ = P/S
Active power factor, phase 1,
P1/S1
Active power factor, phase 2,
P2/S2
Active power factor, phase 3,
P3/S3
Reactive power of the
system
Reactive power, phase 1
(phase-to-neutral L1 – N)
Reactive power, phase 2
(phase-to-neutral L2 – N)
Reactive power, phase 3
(phase-to-neutral L3 – N)
Apparent power of the
system
Apparent power, phase 1
(phase-to-neutral L1 – N)
Apparent power, phase 2
(phase-to-neutral L2 – N)
Apparent power, phase 3
(phase-to-neutral L3 – N)
Power factor of the system
Power factor phase 1
Power factor phase 2
Power factor phase 3
Reactive power factor
sinϕ = Q/S
Reactive power factor,
phase 1, Q1/S1
Reactive power factor,
phase 2, Q2/S2
Reactive power factor,
phase 3, Q3/S3
Energy meter 1
Energy meter 2
Energy meter 3
Energy meter 4
Application
(see Table 2)
A11
A34
A24 /
...
A44
A16
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
33