transmitter and receivers are all working correctly. The frame losses that
led to the hold are not added to the total frame losses.
Note: A servo extension can be used to allow the Flight Log to more
conveniently be plugged in without having to remove the aircraft's hatch or
canopy. On some models, the Flight Log can be plugged in, attached and
left on the model using double-sided tape. This is common with helicopters,
mounting the Flight Log conveniently to the side frame.
QuickConnect
(Brownout Detection not available with DSMX)
The remote receivers now included with the AR9110 feature QuickConnect
with Brownout Detection (Brownout Detection not available with DSMX). Should
a power interruption occur (brownout), the system will reconnect immediately
when power is restored and the LEDs on each connected receiver will flash
indicating a brownout (power interruption) has occurred. Brownouts can be
caused by an inadequate power supply (weak battery or regulator), a loose
connector, a bad switch, an inadequate BEC when using an electronic speed
controller, etc. Brownouts occur when the receiver voltage drops below 3.2
volts thus interrupting control as the servos and receiver require a minimum
of 3.2 volts to operate.
How Brownout Detection Works
When the receiver voltage drops below 3.2 volts the system drops out (ceases
to operate). When power is restored, the receivers will immediately attempt
to reconnect transmitter was left on, the system reconnects, typically about
4ms. The receivers will then blink indicating a brownout has occurred (DSM2
only). If at any time the receiver is turned off then back on and the transmitter
is not turned off, the receivers will blink as a power interruption was induced
by turning off the power to the receiver (DSM2 only). In fact this simple test
(turning the receiver off then on) will allow you to determine if your system's
brownout detection is functioning.
Note: If a brownout occurs in-flight it is vital that the cause of the brownout
be determined and corrected. QuickConnect is designed to allow you to
safely fly through most short duration power interruptions. However, the
root cause of these interruptions must be corrected before the next flight
to prevent catastrophic safety issues.