Herunterladen Inhalt Inhalt Diese Seite drucken

Recommended Spares; Troubleshooting - Nilfisk-Advance IVT 1000 CR Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 36
Refit the filter housing by pressing on the top, to mount
the four screws.
Remount the handle and fix in position with the 2
screws.
The dismounted and replaced exhaust filter must
be covered with a plastic bag and disposed of in the
appropriate way.
Execute the change of the primary filter and of the
exhaust filter with particular care above all use the
mask type P3.
Note
The exhaust filter is toxic waste and must be treated as
such.
Hand it over to one of the authorities authorized to
dispose of such materials.
12. — Recommended spares
The following is a list of spare parts that should be kept
ready at hand in order to speed up maintenance work.
Part no.:
Description:
02171000
DUST SAFE
81620000
DUST BAG 6.5 L, 5 PCS
80556600
ULPA FILTER KIT
80353000
SEALING FOR INLET
61909800
GORE-TEX FILTER
80386700
SEALING FOR CONTAINER
Specifications
Rated power W
DUST CLASS
FREQUENCY (Hz)
GROUNDED
Protection grade (moist., dust) –
Airflow without hose l/sec
Vacuum kPa
VACUUM MAX (KPA)
Suction power with hose W
Sound pressure level at 1.5 m (ISO 3744)
MAIN FILTER TYPE
Main filter area cm2
Exhaust filter, ULPA, surface area U15 cm2
Container capacity l
Dust bag capacity l
INLET (MM)
LENGTH X WIDTH X HEIGHT (CM)
Weight kg
Specifications and details are subject to change without prior notice.
13. — Trouble-shooting
• the motor will not start
-
-
• the suction power is reduced
-
-
-
The by pass valve protects the motors against an
overheating that may occur when there is not enough
cooling air.
You should not release this mechanism unnecessarily
by closing the suction inlet with your hand while the
machine is working.
When the hose or the tube is blocked or the filter
needs to be cleaned, the airflow is interrupted or not
longer sufficient and the by pass valve opens. It is not
necessary to shut down the system while removing the
blockage.
Having done that, you may continue with your work.
• the vacuum cleaner stops
-
-
IVT1000 CR
IVT1000 CR H
EU - UK
EU –UK
220-240V
220-240V
1200
1200
M
H
50-60
50-60
JA
JA
IP40
IP40
38
35
19,8
20
19,8
20
250
236
61
61
GORETEX PTFE
HEPA H13
2100
2573
2573
2573
12,5
12,5
6,5
8
32
32
Ø30 x 62,5
Ø30 x 72,5
7,75
9,2
a fuse may have blown and needs replacing.
the cable or the wall socket may be defective and
needs checking.
the dust bag may be full and needs replacing,
the filter may be clogged and needs shaking,
The by pass valve is open
the thermal cut-out has switched off the motor
as a result of an obstruction of the hose, wand or
nozzle. Remove the cause of the obstruction.
when the motor is cool, it will automatically start
again.
IVT1000 CR
IVT1000 CR
Safe Pack
EU – UK
US
220-240V
110-120V
1200
1100
H
M
50-60
50-60
JA
JA
IP40
IP40
35
36
20
19,6
20
19,6
236
240
61
61
HEPA H13
GORETEX PTFE
2573
2100
2573
2573
-
12,5
6,5
6,5
32
32
Ø30 X 70
Ø30 x 62,5
8,2
7,75
IVT1000 CR H
IVT1000 CR
Safe Pack
US
US
110-120V
110-120V
1100
1100
H
H
50-60
50-60
JA
JA
IP40
IP40
34
34
19,8
19,8
19,8
19,8
232
232
61
61
HEPA H13
HEPA H13
2573
2573
2573
2573
-
12,5
6,5
8
32
32
Ø30 X 70
Ø30 x 72,5
8,2
9,2
35

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ivt 1000 cr h

Inhaltsverzeichnis