Herunterladen Inhalt Inhalt Diese Seite drucken

Sony VPL-HW65 Kurzreferenz Seite 22

Video projector
Vorschau ausblenden Andere Handbücher für VPL-HW65:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 60
7
Remove the filter holder.
8
Remove the air filter.
9
Attach the new air filter so that it fits
into each claws (10 positions) on the
filter holder.
Note
Attach the air filter aligning it with the
shape of the filter holder.
Also, do not touch the fan after removing
the air filter that is set deep inside the
projector.
10
Attach the filter holder.
Note
The projector will not turn on unless the
filter holder is securely closed.
22
GB
11
Wipe dust off the ventilation holes
(intake) with a soft cloth.
Ventilation holes (intake)
12
Place the unit back on its original
position.
13
Turn on the unit, then select the lamp
setting item on the Setup
The menu screen below will be
appeared.
Claws
Tip
If "Settings Lock" is set to "Level B," set to
"Off" once.
14
Select "Yes."
Caution
Do not put your hands into the lamp
replacement slot, and do not allow any liquid
or other objects into the slot to avoid
electrical shock or fire.
Notes
• The unit will not turn on unless the lamp is
securely installed in place.
menu.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vpl-hw45

Inhaltsverzeichnis