Master / Slave Mode
Set the Master device to Auto (P) or Sound Control (SoUd) mode.
To set the respective Slave devices, press the MODE button until each display shows SLAV.
In order set Slave mode, press the MODE button until each display shows PEVE.
You can choose the desired mode via the UP and DOWN buttons:
ON = Slaves controlled by Master device (ON=default setting)
OFF = Slaves function inversely from the Master device.
DMX-CONTROLLED OPERATION
You can control the devices individually via your DMX-controller.
DMX MODE
The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from
which the LED SCY-200 TCL DMX will respond to the controller.
Addressing
Press the MODE button until the display shows Addr. You can now set the desired address via the UP or
DOWN buttons.
Setting the DMX Start Address:
Mode:
Add
Controlling:
After having addressed the LED SCY-200 TCL DMX, you may now start operating it via your lighting
controller.
Note:
It's necessary to insert the XLR termination plug with 120
proper transmission on the DMX data link.
Choosing a DMX Channel Mode with 7 or 20 Channal Occupation
The device has 2 DMX-modes. The Control Board allows you to assign the DMX-Mode.
Setting DMX Mode
After setting the desired address via the UP or DOWN buttons, press the MODE button again and the
display shows 7_CH.
In case you would rather select the 20-channel mode, press the DOWN button in order to choose the 20_CH
setting.
Mode:
7_CH (default setting)
Value:
1 - 512
Value:
20_CH
in the last lighting in the link in order to ensure
22/26