DEVICE DESCRIPTION

Features

Classic beam effect as TCL Version
1 row of 6 glass lenses • Each lens can be controlled individually via DMX • DMX512 control via regular DMX
controller (occupies max. 20 channels) • 7 or 20 DMX channels selectable for numerous applications •
Sound controlled via built-in microphone • Microphone-sensitivity adjustable via rotary-control • Strobe effect
• Auto mode • Internal programs • Master/Slave function • Addressing and setting via control panel with 4-
digit LED display and three operating buttons • Additional controlling possiblity via the EUROLITE RC-2
remote control (not included in delivery) • Rugged, compact housing in a striking design • Innumerable uses •
Ideal for bands, stages or solo entertainers • Equipped with 6 x 3 W Tricolor LEDs • Particularly bright
illuminating power of the TCLs • Mounting bracket for installation on a truss system included • Locking
possibility at the mounting bracket • Ready for connection via IEC power cord with safety plug

Overview

1
2
3
Power supply: 230 V AC, 50 Hz~
Fuse: T 1 A, 250 V
1. Power out
2. Fuse
3. Power supply
4. Attachment eyelet
5. DMX In
6. DMX Out
7. Operating buttons
8. Control panel with 4-digit LED display
9. Microphone
10. Sensitivity control
11. Remote control socket

INSTALLATION

Overhead rigging

Please consider the EN 60598-2-17and the respective national standards during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
5
4
6
LIGHTING CONTROL
PROTOCOL DMX-512
DMX IN
XLR occupation:
1: Ground
2: Signal (–)
3: Signal (+)
Safety rope
Power out
DANGER TO LIFE!
7
8
DMX OUT
MODE
18/26
9
10
11
Microphone
UP
DOWN
Remote control