Presetting servos
Using CV no. 122 preset the first hold position of the servo (hold posi-
X
tion "red"), giving it the value "40" for instance.
Using CV no. 123 preset the second hold position of the servo (hold
X
position "green"), giving it the value "100" for instance.
Using CV no. 125 preset the amplitude of oscillation of the first hold posi-
X
tion of the servo (hold position "red"), giving it the value "35" for instance.
Using CV no. 126 preset the rocking time of the first hold position of
X
the servo (hold position "red"), giving it the value "90" for instance.
Using CV no. 127 preset the amplitude of oscillation of the second hold posi-
X
tion of the servo (hold position "green"), giving it the value "70" for instance.
Using CV no. 128 preset the rocking time of the second hold position of
X
the servo (hold position "green"), giving it the value "125" for instance.
Transfer the values so preset to the Servo Control.
X
The presettings are saved.
X
EN
Description of Return motion (CV 129,139,149,159)
ADVICE: Values >0 will cause the servo to move to the position "green"
whenever key "green" is actuated, and to move back to the position "red"
after the time set in CV 129,139,149,159 has gone by. If key "red" is actu-
ated, the servo will move to the position "red" even if the time preset has
not gone by yet.
Description of Permanent working, in particular for CV programming
ADVICE: In permanent working mode the servo continuously moves to and
fro between both preset positions without requiring any external control
signal. For that operating mode the address in CV 120,121 for output 1, in
CV 130,131 for output 2, in CV 140,141 for output 3 or in CV 150,151 for
output 4 has to be set to zero. This can be done by means of DCC CV pro-
gramming or by means of key programming via Path 1. It is not possible to
preset permanent working via Path 2.
48
ANLAGENBAU
Synopsis of all configuration variables
ANLAGENBAU
CV
Description
112
Software version
113
Manufacturer's code (Manufacture ID)
119
Decoder configuration
Bit0 = 1:
Voltage at output 1 is
always switched on
Bit0 = 0:
Voltage at output 1 is
switched on only when
servo is in motion
Bit1 = 1:
Voltage at output 2 is
always switched on
Bit1 = 0:
Voltage at output 2 is
switched on only when
servo is in motion
Bit2 = 1:
Voltage at output 3 is
always switched on
Bit2 = 0:
Voltage at output 3 is
switched on only when
servo is in motion
Bit3 = 1:
Voltage at output 4 is
always switched on
Bit3 = 0:
Voltage at output 4 is
switched on only when
servo is in motion
Bit4:
Is not used
Bit5:
Is not used
Bit7 = 0:
DCC operation
Bit7 = 1:
Motorola operation