Herunterladen Inhalt Inhalt Diese Seite drucken

General Features; General Notes - Beninca PREMIER Betriebsanleitung

Elektromechanische automation für schiebegitter
Vorschau ausblenden Andere Handbücher für PREMIER:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
• Before installation, carefully read the instructions hereunder.
• It is strictly forbidden to use the item PREMIER for applications other than the intended uses described in
these instructions.
• Instruct the user on how to use the system.
Thank you for choosing our PREMIER ratiomotor. All items in the wide Benincà production range are the
result of twenty-years' experience in the automatism sector and of continuous research for new materials
and advanced technologies. We are, therefore, in the position to offer higly reliable products that due to their
power, effectiveness and useful life, fully satisfy the final user's requirements.
All our products are manufactured to the existing standard and are covered by warranty. Possible injury to
people or accidents caused by defects in construction are covered by a civil liability policy drawn up with one
of the major insurance companies.
For a good operation of the automatic system the door to be automated must feature the following character-
istics:
• Rugged and stiff door leaves.
• Efficient hinges.
• The door leaves should be moved by hand without any friction for the entire stroke.
• The doors should be complete with a catch in the closing phase.
In the negative, replace the faulty parts. Reliability and safety of the automatic system depend on the gate
structure.
This automatism has been designed to automatize doors, the dimensions of which do not allow to use tra-
ditional actuators.
It is equipped with an articulated arm and with a limit switch, (PREMIER). The operations are smooth and noi-
seless. It is easy to be assembled and, thanks to its pleasant design, it meets the most demanding needs.
The emergency block is simple and safe thanks to the lever with personalised key.
PR.45E/PR.45EL / PR.45ER:
Brown
Grey or Light blue
Black
Yellow/Green
The limit switch contacts are connected in series to the two motor phases. If, after an opening control, the
motor starts the closing movement, it is sufficient to reverse the brown wire with the black one in the control
unit.
PR.45E24:
Red
Black
Carry out the limit switch connections to the control unit.
If, after an opening control, the motor starts the closing movement, it is sufficient to reverse the red wire with
the black one in the control unit.
As regards the torque adjustments and the operating modes, please read instructions given in the control
unit manual.
The PR.45E unit is equipped with built-in limit switches for both opening and closing phases. Proceed as
follows:
• Release the actuator (see paragraph "Release by hand")
• Remove the cover M from the release lever L.
• Loosen the screw V1 and remove the release lever L.
• Loosen the screws V2 and remove the cover.

General features

Motor phase and capacitor
Common
Motor phase and capacitor
Earth - compulsory pursuant to regulations in force
Motor +
Motor -
To adjust the limit switches (Fig. 3)