only for PF-SOF1-ALT & PF-SOF1,5-ALT
The 2 Simplex systems, that make up a Duplex system,
must be programmed individually; the program does NOT
necessarily have to be the same on the 2 Simplex systems!
1. Press the scroll
button and hold it for 5 sec until the
display shows:
System Check
2. Within 10 sec, press the up
show:
HardUnit:°f
Press the up
or down
unit. Make sure to also adjust/convert the exchange
capacity!
3. Press the scroll
button again; the display will show:
ExCap:5.5°f M3/L
Press the up
or down
exchange capacity per litre of resin.
4. Press the scroll
button again; the display will show:
Resin:XXX liters
Press the up
or down
of resin.
5. Press the scroll
button again; the display will show:
Cycle 1:
Press the up
or down
of the regeneration cycle.
Press the scroll
button again to advance to the next
regeneration cycle.
Cycle 1
Backwash
Cycle 2
Brine draw/slow rinse
Cycle 3
Fast rinse/brine tank refill (PF-SOF1)
Fast rinse (PF-SOF1,5)
Cycle 4
Brine tank refill (PF-SOF1,5)
6. Press the scroll
button again; the display will show:
MTR:SNAP SENSOR
Press the up
or down
water meter sensor.
7. Press the scroll
button again; the display will show:
Exit
Press the up
or down
program into
the
programming level.
8. Repeat steps 1-7 for both Simplex systems.
EN - English
ELECTRONIC CONTROL PANEL
button; the display will
button to set the hardness
button to set the
button to set the volume
XX min
button to set the length
button to set the type of
button to save the
NOVRAM® and
exit the
Page 14