Installation example

1 Liquid gas heater
Trumatic S
2 Truma-Ultraheat
3 Control panel with
thermostat
4 Trumavent fan and
comfort kit with Airmix
(for warm air distribution
– optional), not for
Truma S 55 T
Important
operating notes
1. Repairs may only be
carried out by an expert.
Due to the de-
sign, the heater
front case will
become hot dur-
ing operation. The opera-
tor is obliged to ensure
that due care is taken to
protect third parties (small
children in particular).
2. The heater's hot air outlet
should under no circum-
stances be blocked. Never
hang clothes or similar in
front of or on top of the
heater to dry. This could
cause serious damage to the
heater as a result of overheat-
ing. Do not place inflamma-
ble materials near the heater!
Please observe these instruc-
tions for your own safety.
3. When operating a brand-
new heater for the first time
(or after it has been idle for a
lengthy period) you may tem-
4
porarily notice a slight smoke
and smell. We advise running
the heater at full power and
thoroughly ventilating the
room.
4. Any modifications to the
appliance or the use of spare
parts and accessories impor-
tant for operation which are
not original Truma parts, or
non-observance of the in-
structions for installation and
use will result in the guaran-
tee becoming invalid and no
liability will be assumed. Fur-
thermore, the approval for
operating the appliance will
become invalid and in some
countries also the approval
for operating the vehicle.
Caution: Despite
careful manufac-
ture, the heating
system may contain
sharp-edged components,
and protective gloves should
always be worn when carry-
ing out any maintenance or
cleaning work.
Ultraheat
additional electric heating for
Trumatic S 3002 (P), S 5002 and
Truma S 55 T heaters
3
1
2

Short description

Truma-Ultraheat is an addi-
tional 230 V electric heater
for the LPG heater models
Trumatic S 3002 (P), S 5002
and Truma S 55 T.
Heater operation is basically
possible with gas only, elec-
tricity only or simultaneously
with electricity and gas.
When using simultaneously
the electrical unit will switch
itself off before overheating
occurs as a result of the
stronger gas burner.
When using electrical only
we recommend to set the fan
control on position 3 (manual
or auto), remembering to set
the output level to 2000 W
(ensure that the fuse protec-
tion for the power supply of
the camp site is sufficient).
If more than 2000 W are re-
quired (heating up/cold tem-
peratures) you must refer
back using gas operation as
the 230 V electrical operation
is a secondary heater only.
4
The heater operation is re-
gardless of the operating
mode (gas oder electricity)
also possible without the
Trumavent fan.
To ensure an even and rapid
warm air distribution as well
as lower surface tempera-
tures on the heating unit, we
do recommend that you al-
ways operate the heater with
a running Trumavent warm
air system.
If your Ultraheat is fitted with
a remote sensor (accessory),
do not position it near any
heat source (oven, lights, op-
posite of blown air outlets
etc.) or near a confined area
where heat can accumulate
(under a shelf, near corners,
behind curtains).

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis