Technical service.
To achieve the best results during the counting it is necessary to follow required
instructions:
- Switch off the counter when it during the long time isn't used.
- Wipe a dust from hopper and stacker by dry, clean stuff. In case of pollution,
sensor controls (detectors) can give the incorrect information and counter can
define original banknotes as a counterfeits.
- It is recommended to carry out technical service and preventive measures of
device, including the partial counter disassembling by the service engineer,
detectors adjustment each 30 days in the service center by the professional, and
more often at a heavy using
10
System errors (They are displayed at once at counter switching on):
Code
CHECK
Hopper sensor is blocked by
HOPPER
banknotes or is dirty
SENSOR
CHECK
Stacker sensor is blocked by
STACKER
banknotes or is dirty
SENSOR
CHECK
The left / right IR count sensor is
LEFT/RIGHT IR
polluted or doesn't work
CHECK SPEED
Speed sensor is either dirty or
SENSOR
failed
CHECK MOTO
Counter's motor operation error
SENSOR
MESSAGE
Memory error
ERROR
28
Reason
Remove banknotes from the hopper, or clean the
sensor.
Remove banknotes from the stacker, or clean the
sensor.
Contact the service center.
Contact the service center.
Contact the service center.
Error codes.
Solution