8. Internal Jumper Settings

This system has jumpers on the PCB in the device. Their function is explained in the following:
The exit delay duration cannot be determined. The exit delay is set to 60 seconds ex works.
MISC.
FUNCTIONS
ON OFF
RINGBACK
ENTRY DELAY
(SECONDS)
15
30
60 90
ALARM
DURATION
(MINUTES)
3
5
15
"MISC. FUNCTIONS"
Determines whether a confirmation is to be output through the acoustic signalling
device output (terminal clamp 5) when the system is activated or deactivated.
Position "ON"
The relay of terminal clamp 5 is activated twice briefly, when the system is
activated. The relay of terminal clamp 5 is activated once briefly, when the system
is deactivated.
Position "OFF"
The relay of terminal clamp 5 is not activated.
"ENTRY DELAY (Seconds)"
This jumper determines the duration of the entry delay. The entry delay is activated
when a sensor/detector in alarm zones 1 or 5 triggers when the system is activated.
The following values can be set: 15 seconds, 30 seconds, 60 seconds, 90 seconds.
"ALARM DURATION (Minutes)"
This jumper determines the alarm time duration for terminal clamp 5.
The following values can be set: 3 minutes, 5 minutes, 15 minutes, and permanent
alarm until the system is deactivated.
Observe the applicable statutory and municipal provisions!
The longest acoustic alarm duration permitted in Germany is 3 minutes. There may,
however, be different provisions on this time in certain municipalities and towns.