6. Technical data and measuring tolerances

6.1 Technical data
1
Display..............................: 3
value 1999
Polarity display ................: „-", automatic
Overload indicator...........: "1" or "-1" is displayed
Measuring method ..........: Dual Slope
Measuring rate ................: 1-2 measurements per second
Operating voltage ...........: 9 VDC (= direct voltage), stabilised
Current consumption ......: approx. 1.5 mA
Operating temperature...: 0°C to +50°C, rel. air humidity < 85%,
non-condensing
Mass..................................: approx. 85 g
Dimensions WxHxD.........: 72 x 36 x 71 mm
Installation ......................: in accordance with DIN 43700, Type 2;
dimensions WxH
33 x 69 mm (recess size)
12
/
-digit LCD display, max. display
2
6.2 Measuring tolerances
The accuracy of the measurement results is valid for a tempera-
ture of +23°C ± 5 K, at a relative air humidity of < 85 %, non-con-
densing.
Statement
of
+ number of digital point errors = digits = dgts).
Measuring
Accuracy
range
±(0.5%+1dgt)
200 uA
±(0.5%+1dgt)
2
mA
±(0.5%+1dgt)
20 mA
±(0.5%+1dgt)
200 mA
±(0.5%+1dgt)
2
A
accuracy:
±
(%
of
reading
max.
Resolution
input level
200 uADC
0.1 uV
0.001 mA
2 mADC
0.01 mA
20 mADC
200 mADC
0.1 mA
2 ADC
0.001A
13