uk │ 12. Cleaning

12. Cleaning

Cleaning intervals depend on the build-up of
dust and dirt and cannot be determined in
advance.
Guide value: Low levels of dirt build-up
require semi-annual cleaning intervals.
1. Remove all layers of dust and dirt from the
inside of the air channel regularly.
2. Clean the fan with a dry cloth, particularly
after it has not been used for a longer
time.
Information
● Do not use aggressive cleaning agents.
● Make sure that there is no dirt in the air
channel.

13. Fault rectification

● Call on the services of a trained electrician
any time there is a fault.
● Repairs should only be carried out by a
trained electrician.
Danger to life from electric
shock.
Prior to accessing the
DANGER
connection terminals, switch off
all supply circuits. Switch off the
mains fuse, secure against
being accidentally switched
back on and position a visible
warning sign.
Danger of burning through an
overheated motor, in the case
of a fault.
CAUTION
Let the device cool down
sufficiently before working in the
area of the motor. Only then
remove the protective grille [2].
20
Fault
Cause, measure
Fan does not
No mains voltage.
switch on.
Check whether the mains
fuse has failed. Switch on
if necessary.
Motor protection
Overload through dirt,
switch has
bearing damage, etc.
triggered.
Check whether this
electrician-installed switch
has triggered (Position
"Off").
Switch the mains fuse off.
Fit warning sign.
Check whether the impeller
can be turned without
rubbing and without any
increased resistance.
Remove any dirt, switch the
motor protection switch on,
switch the mains fuse on.
Impeller is blocked.
Fan does not
switch on.
Repairs may only be
carried out by a trained
specialist
Check impeller and clean if
necessary.
Impeller not
Switch off unit. Ensure that
turning.
the impeller is not blocked
by foreign bodies.
Fan doesn't
Impeller is rubbing.
start up. Motor
overheats.
If the fault still continues or occurs
again, disconnect the fan from the
power supply at all poles.
Let a certified electrician determine
the cause of the fault and eliminate
it.