Function Setting Commands
Operation
Function
Commands
Description
[Program Password]+[#]
Enter settings
[*] + [#]
Enter settings
[20] + [1~8] + [#]
Coding of Remote Controller
[21] + [1~8] + [#]
Delete Remote Controller
[23] + [01~99] + [#]
Coding of Defense Zones
[24] + [01~99] + [#]
Delete Defense Zones
[30] + [Password] + [#]
Change Program Password
[31] + [Password] + [#]
Change Program
Password
[32] + [AA] + [BB] + [CC] +
System Time Setting
[DD] + [EE] + [FF] + [#]
[33~35] + [AA] +
Timely Arm
[BB] + [#]
[36~38] + [AA] +
Timely Disarm
[BB] + [#]
[39] + [0/1] + [#]
Timing Control: turn on/ off the
function of timely arm/disarm
[41] + [0/1] + [#]
Wireless
Transmission Control
[42] + [01~99] + [#]
Wireless Siren Coding Encryption
[44] + [01~99] + [#]
Out Arm Delay Time Setting
[45] + [01~99] + [#]
Alarm Delay Time Setting
[51]~[56] +
Alarm Number Setting
Phone number + [#]
[51]~[56] + [#]
Delete Phone Number
[57]~[59] +
SMS Receiving Number Setting
Phone number + [#]
[57]~[59] + [#]
Delete SMS Receiving Number
[60] + [AA] + [B] +
Defense Zone
[C] + [D] + [#]
Programming
ENGLISH
28
Remarks
Default password: 8888
Max 8 remote controllers
Defense Zones Number: 01~99
Defense Zones Number: 01~99
Default: 1234
Default: 8888
[AA]: year [BB]: month[CC]: date
[DD]: hour [EE]: minute [FF]: second
3 groups of auto arm time
[AA]: hour [BB]: minute
3 groups of auto disarm time
[AA]: hour [BB]: minute
0: OFF 1: ON
0: OFF 1: ON
Siren coding number: 01~99
Default: 60seconds
Default: no delay
6 groups of alarming user number
3 groups of SMS receiving number
AA: Defense zone number: [01~99]
B: Defense zone type: [1] real-time
[2] 40 seconds delay
[3] 24 hours
[4] bypass
C: Defense zone location:
[1] SOS Alarm
[2] Fire Alarm
[3] Gas Leak Alarm
[4] Door Alarm
[5] Hall Alarm
[6] Window Alarm
[7] Balcony Alarm
[8] Boundary Alarm
D: Siren ON/OFF
[0] OFF
[1] ON
Function Setting Commands
[61] + [01~12] +
Home Arm Defense Zone Setting
[0/1] + [#]
[70] + [1] + [#]
Voice Recording
[75] + [0/1] + [#]
Siren Setting
[76] + [0/1] + [#]
Siren Setting in Emergency Help
mode
[77] + [1/0] + [#]
SMS Notification for Arm/ Disarm
[81] + [#]
GSM Signal Checking
[83] + [0/1] + [#]
Arm/ Disarm Voice Prompt
[84] + [0/1] + [#]
Voice Prompt for All Settings
[88] + [#]
IMEI Checking
[*] + [0] + [#]
Alarming Record Checking
[95175308246] + [#]
Factory Reset
[operation password] + [1]
Arm by SMS
[operation password] + [2]
Disarm by SMS
[operation password] + [3]
Alarm Record Checking by SMS
[operation password] + [4]
Turn on 12V output
[operation password] + [5]
Turn on 12V output
Note:
The last five functions could be realized only when the GSM signal intensity
reaches 20.
Declaration of Conformity
This attesting conformity with the following directives / standards:
Electromagnetic Compatibility Directive 2004/108 / EC
EN 55013: 2001 + A1: 2003 + A2: 2006
EN 55020: 2007
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
Low Voltage Directive 2006/95/EG
EN 60065: 2002 + A1: 2006 + A11: 2008
Defense zone number: 01~12;
[0] Home arm but not alarm;
[1] Home arm and alarm
10 seconds
[0]: off (default); [1]: on
[0]: off (default); [1]: on
Intensity: 07-31 (if its less than 07,
you should change place.)
[0]: off; [1]: on (default)
[0]: off; [1]: on (default)
[AA]: year [BB]: month[CC]: date
[DD]: hour [EE]: minute [FF]: second
Press 2: upturn
Press 8: downturn
Press [*#]: Exit
Use with caution
Default operation password: 1234
Default operation password: 1234
Default operation password: 1234
Default operation password: 1234
Default operation password: 1234
ENGLISH