Function settings
17. Delete Phone Number
In setup state, input 51~56, and then press # to confirm, the main unit will make a
long beep and the Signal indicator will flicker once and you will hear "delete comple-
ted", which indicate the alarming user number is deleted successfully.
Operating method: XX a #
XX indicates: the 1- 6 alarming user number 51~56
For example: Delete the third alarming user number
from the system.
Operating method: 53 a #
18. SMS Receiving Number Setting
SMS Receiving number means when system is alarming, it will send SMS to this
mobile number. You can set maximum 3 SMS numbers.
In setup state, input 57~59, then input the SMS receiving number, and then press
# button to confirm. The main unit will make a beep, the Signal indicator will flicker
once and you will hear "setting completed", which indicate setup successfully.
Operating method: XX a YY...YY a #
XX indicates: address codes of message-receiving numbers from the
first group to the third group 57~59
YY...YY indicates: the SMS receiving number
For example: setup 13822222222 as the first SMS receiving number
Operating method: 57 a 138222222 a #
Note:
The sms-receiving number can be maximum 15 digits.
ENGLISH
14
Function settings
19. Delete SMS Receiving Number
In setup state, use keypad to input 57~59, and then press # button to confirm. The
main unit will make a beep, the Signal indicator will flicker once and you will hear
"delete completed", which indicate SMS number is deleted successfully.
Operating method: XX a #
XX indicates: address codes of SMS receiving numbers from the first
group to the third group 57~59
For example: delete the first SMS user number from the system
Operating method: 57 a #
20. Defense Zone Programming
If you want to change the alarm attribute of defense zone, such as turnoff the siren
when system alarms, you can do it by defense zone programming. In setup state,
first input 60, then the defense zone number 01~99, then input defense zone type
1~4, then input alarm type 1~8, and then select siren on/off 0/1, at last press # to
confirm. You will hear the main unit emit a long beep and a voice prompt "setting
completed".
Operating method: 60 a AA a B a C a D a #
AA: defense zone number 01~99 means zone 1 to zone 99;
B: defense zone type
1: real-time defense zone
2: 40 seconds delay defense zone
3: 24 hours defense zone
4: bypass defense zone
C: alarm type
1 SOS Alarm
2 Fire Alarm
3 Gas Leak Alarm
4 Door Alarm
5 Hall Alarm
6 Window Alarm
7 Balcony Alarm
8 Boundary Alarm
D: siren ON/OFF: 0 OFF, 1 ON
For example: set defense zone 12 to be 24-hour, fire alarm and siren on
Operating method: 60 a 12 a 3 a 2 a 1 a #
Note:
The programming is suitable for
all defense zones including wired
defense zones.
ENGLISH
15