Switch the Pressure Measuring Adapter to the appropriate desired
units of measurement (metric, kPa; or British/American, psi) and set
the connected Voltmeter to the 200mV DC measuring range.
If the Voltmeter indicates a voltage on a pressure-free System, then
setting "ZERO" must be carried out.
If the Voltmeter is overloaded while measuring pressure (usually in-
dicated by "OL" for "Overload"), then set the Voltmeter to the next-
B Negative pressure (vacuum) measurement
The maximum-permitted vacuum input level must
not be exceeded under any circumstances.
. . . . < 1
Connect no voltages to the Pressure Measuring Ad-
apter; it tan be destroyed by this.
Switch the Pressure Measuring Adapter to the appropriate desired
units of measurement (metric, cmHg; or British/American, inHg)
and set the connected Voltmeter to the 200mV DC measuring ran-
ge. If the Voltmeter indicates a voltage on a pressure-free System,
then setting "ZERO" must be carried out.

Disposal

If the Pressure Measuring Adapter does not function in spite of
good supply (9V battery) or is no longer repairable (fracture in the
measuring transducer or threaded connection), then it must be dis-
posed of in accordance with applicable statutory regulations.
12
Rectification of fauits
With the Pressure Measuring Adapter PS 403, you have acquired a
dards and is safe in Operation. However, Problems or faults tan ari-
se. Because of this, the following describes how some of these
observe the safety information without fail!
Possible Cause
Fault
No indication
Is the Pressure Measuring Adapter
on Voltmeter
connection to the Voltmeter firm and is the
polarity correct?
Is the Pressure Measuring Adapter battery
empty?
Is the System pressure-free?

Service and care

Battery changing tan be found under "Handling, Putting into ope-
To clean the Pressure Measuring Adapter and measuring transdu-
cer, use a clean, lint-free, anti-static, dry cleaning cloth.
D
not use any carbonaceous cleaning agents or
O
: . '
surfaces of the Pressure Measuring Adapter and
measuring transducer will be attacked. Additionally,
the fumes are explosive and endanger health. D
not use any sharp-edged tools, screwdrivers, metal
brushes or similar for cleaning.
O
13