SET UP

Place the machine on a plane surface and connect the remote control to the 5-pin socket REMOTE.
Fill the tank with smoke fluid.
The fluid tank needs to be filled with smoke fluid before starting operation and always disconnected
from the mains as fluid could be spilled.
Only use quality smoke fluids available at your dealer. We recommend high-quality EUROLITE
smoke fluids (e. g. EUROLITE Smoke Fluid "P" professional, 5 l). You must not use substances that
are classified as "dangerous working material" or "inflammable fluids".
.
..............................................................................................................................................................................

Installation

Install the device in a well-ventilated area.
• The operation in an insufficiently ventilated room can lead to a condensation of the smoke fluid. The
resulting slippery surface can cause accidents. Keep a minimum distance of 20 cm around and above the
device.
• Furthermore do not orientate the escape nozzle directly in the direction of the audience's eyes. In order to
create a good effect, there should be a distance between the device and the audience of at least 1.5 m.
• Only install the smoke-machine on scratch resistant and water resistant surfaces.
• Please make sure that the inclination angle does not exceed 15°.
• This device is constructed for standing installation only.
..............................................................................................................................................................................

Connection with the Mains

Connect the device to the mains with the power plug.
The occupation of the connection cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green Earth
The earth has to be connected! If the device will be directly connected with the local power supply network, a
disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent electrical
installation. The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum fault current
of 30 mA.