Practice using your PullzAll
Pulling or Lifting Procedure
before you pull or lift a load. A real
situation is no time to be learning
how to pull or lift using a single
how to use your PullzAll.
line rigging technique. Double or
Knowing the proper pulling
multiple line rigging techniques
and lifting techniques can help
follow the same basic steps but
keep you and others around
use a snatch block to assist the
you safe. And perhaps the most
process. For details, see the
important part of the pulling
"Rigging Techniques" section in this
process, regardless of the situation,
manual.
is what you do before you pull.
In this guide, you are shown
Step 1: PUT ON GLOVES AND
the basic fundamentals for effective
ATTACH HOOK STRAP. Ensure
pulling/lifting. However, it is up to
the hook strap is attached to the
you to analyze the situation and
hook with latch on the wire rope,
make the decisions necessary for
not the swiveling anchor hook.
the proper use of your PullzAll.
Apply your knowledge of your
PullzAll and the basic fundamentals
you have practiced to adjust
your techniques to each unique
situation.
Some keys to remember when
using your WARN PullzAll:
Step 2: CONNECT TO POWER
1. Always take your time to
SOURCE.
assess your situation and plan
Corded 230 VAC PullzAll
your pull or lift carefully.
2. Always take your time when
1)
using a PullzAll.
3. Use the right equipment for
2)
your situation.
4. Always wear leather gloves
and do not allow the wire rope
to slide through your hands.
3)
5. Only one person should
operate the PullzAll while
Cordless 24V DC PullzAll
pulling a load.
6. Think safety at all times.
1)
7. Practice. Practice and
2)
practice the steps.
3)
WARN INDUSTRIES * THE BASIC GUIDE TO UTILITY PULLING

OPERATING THE PULLZALL

The following steps describe
WARNING
Always use
supplied hook
strap to hold hook
when spooling
rope in or out.
Always use
properly grounded
230Vac 50 Hz
single phase
receptacle
protected by a
ground fault circuit
interrupter (GFCI).
Never remove
ground pin from
plug.
Connect the PullzAll power
Never operate this
cord to a properly grounded,
AC product in a wet
3-prong electrical socket.
environment.
Verify that power cords and
Never route
extension cords are positioned
electrical cables
so that the wire rope or mov-
across sharp edges.
ing load will not damage the
Never route
cords.
electrical cables
Verify that extension cords are
through or near
rated for 15 Amps.
moving parts.
Never route
electrical cables
near parts that
become hot.
Ensure the battery pack is fully
charged.
Verify the power switch is in
the 'Off' position.
Slide battery pack into the
body, making sure that the
latch is fully engaged. The
battery release button must be
in the top position.
15
OPERATING THE PULLZALL
WARNING
Always use
suitable anchor
point capable of
handling load.
WARNING
Never spool out
past red paint on
wire rope.
WARNING
WARNING
Always keep
hands and
clothing clear of
the rope, hook
and fairlead
opening during
operation and
when spooling.
WARNING
Never hook
wire rope back
onto itself. This
damages the
rope.
CAUTION
The Corded 230
VAC PullzAll has
some delay in the
trigger control
use the slow
spooling speed
and release the
trigger early to
prevent from
spooling the
hook loop into
the fairlead.
Step 3: POWER ON THE
PULLZALL. Flip the power switch
to the 'On' position. Always leave
the power switch in the 'Off'
position when the PullzAll is not in
use.
Step 4: SPOOL OUT WIRE ROPE
TO LOAD. Press the directional
switch to 'spool out'. Always keep
tension on the wire rope while
spooling in and out. The wire rope
may unwind inside the PullzAll unit
causing bird nesting and binding,
leading to wire rope damage.
Spooling Alone: Attach the hook
with latch to an anchor point and
walk the PullzAll away from the
load.
Spooling with an Assistant: Have
the person handling the rope hold
the hook strap and walk the wire
rope away from the PullzAll while
spooling out the wire rope.
NEVER spool the wire rope out
past the red paint on the wire rope.
The red paint is visible when 13 ft.
(3.9 m) of wire rope is unwound.
Doing so can cause the wire rope
to spool on the drum in the wrong
direction. This can damage the
wire rope and fairlead.
WARN INDUSTRIES * THE BASIC GUIDE TO UTILITY PULLING
16
Step 5: ATTACH TO ANCHOR
POINT. Attach the PullzAll to an
anchor point using the swiveling
anchor hook. That is capable of
handling the load.
Step 6: PLAN TO PULL. Line
up your pull as straight ahead
as possible. This prevents side
pulls that can allow the wire rope
to rub on the fairlead. Also, side
pulls cause the wire rope to stack
up at one end of the drum. This
can damage the wire rope or the
PullzAll.
Step 7: SECURE TO THE LOAD.
Establish a load point. Often a load
does not have a secure load point.
It may be necessary to secure the
load with a choker chain or a load
strap.
Step 8: ATTACH THE CLEVIS/D-
SHACKLE. Attach the shackle to
the two ends of the strap or chain
being careful not to over tighten
the shackle (tighten and back-off
1/2 turn). Secure the shackle into
the throat of the PullzAll hook.
Step 9: PUT WIRE ROPE UNDER
TENSION. Press the directional
switch to 'spool in' wire rope.
Use the trigger control to slowly
wind the wire rope until no slack
remains. Tension in the wire rope
will keep it from bird nesting and
binding. Once the wire rope is
under tension, stand well clear,
and never step over the wire rope.
Step 10: CHECK YOUR LOAD.
Ensure all connections are
secured and free of debris before
continuing with the procedure.