Sequential command.
Operation complete message generated immediately after <rmt> is sent.
Returns the set voltage in Volts in <nr2> numeric format.
The syntax of the response is
Example:
I?
Sequential command
Operation complete message generated immediately after <rmt> is sent.
Returns the current limit in Amps in <nr2> numeric format. The syntax of the response is
Example:
OVP?
Sequential command.
Operation complete message generated immediately after <rmt> is sent.
Returns the OVP value in Volts in <nr2> numeric format. The syntax of the response is
Example:
VO?
Sequential command
Operation complete message generated immediately after <rmt> is sent.
Reads and returns the output voltage in Volts in <nr2> numeric format. The syntax of the
response is
Example:
IO?
Sequential command
Operation complete message generated immediately after <rmt> is sent.
Reads and returns the output current in Amps in <nr2> numeric format. The syntax of the
response is
Example:
IO? will be 0.934A<rmt>.
If the set voltage is 12.55 Volts the response to the command V? will be
V 12.55<rmt>.
If the current limit is 1·000 Amps the response to the command I? will be
I 1.000<rmt>.
If the OVP value is 33.00 Volts the response to the command OVP? will be
OVP 33.00<rmt>.
If the output voltage is 12·55 Volts the response to the command VO? will be
12.55V<rmt>.
If the output current is 0·934 Amps the response to the command
V<nr2><rmt>
I <nr2><rmt>
OVP <nr2><rmt>
<nr2>V<rmt>
<nr2>A<rmt>