steel pipe with fittings complying with local
regulations, or by means of a continuous
surface stainless steel hose complying with
local regulations.
If you see any abnormalities do
not repair the pipe, contact local
After Sales Service (refer to the
Service chapter).
The connection must be installed correctly,
fixed into hob connection pipe. Otherwise it
will cause leakage of gas.
Warning! Once the installation is
complete, check the perfect seal
of every pipe fixing. Use soapy
water, never flame.
Electrical connection
The electrical work necessary to install the
appliance must be done by a qualified
electrician or competent person, according
to the current regulations.
Before connecting, check that the nominal
voltage of the appliance stated on the
rating plate, corresponds to the available
supply voltage. Also, check the power
rating of the appliance and ensure that the
wire is suitably sized to suit the appliance
power rating (refer to the Technical data
chapter).
The rating plate is located on the lower
casing of the hob.
The appliance is supplied with a connection
cable. This has to be provided with a
proper plug, able to support the load
marked on the identification plate (refer to
the Technical data chapter).
The plug has to be fitted in a proper socket.
If connecting the appliance directly to the
electric system, it is necessary that you
install a double pole switch between the
appliance and the electricity supply, with a
minimum gap of 3 mm between the switch
contacts. The double pole has to be of a
type suitable for the required load in
compliance with the current rules.
The connection cable has to be placed in
order that, in each part, it cannot reach a
90 °C temperature. The blue neutral cable
must be connected to the terminal block
marked with "N". The brown (or black)
phase cable (fitted in the terminal block
contact marked with "L") must always be
connected to the live phase.
Electrical Requirements
The manufacturer declines any
liability if these safety measures
are not observed.
This hob is designed to be connected to a
220-240 V 50/60 Hz AC electrical supply.
Before switching on, make sure the
electricity supply voltage is the same as that
indicated on the hob rating plate. The
rating plate is located on the bottom of the
hob.
The hob is supplied with a 3 core flexible
supply cord.
Upon completion there must be no cut, or
stray strands of wire present and the cord
clamp must be secure over the outer sheath.
Replacement of the connection cable
Warning! The replacement of
electric cable must be carried out
exclusively by the After Sales
Service or by personnel with
similar competencies, in
accordance with the current
regulations.
If the connection cable must be replaced,
only a type H05V2V2-F T90 cable must be
15