4.2 Auxiliary Data Visualization Mode
The system presents an auxiliary data visualization mode. For entering this
mode, press the keys
and
first auxiliary
which indicates compressor total hours of operation.
Example:
means 129.112 one hundred-twenty-nine thousand one hundred twelve hours.
Press
or
to alternate between the other indications, regarding the
following table.
To exit this mode press
.
The following table shows the auxiliary data indications and their meaning.
for 3 seconds. The panel will indicate the
Indication
Description
Compressor total hours of operation shown in
format 00 00 00
Generator voltage - indicated in VDC
Temperature of duct sensor (in case there is heating)
Control panel software version
Relay board software version
Percentage of motor valve opening (in case there is heating)
Battery voltage - indicated in VDC
Reset parameters to preset values. This option can be used
when it is convenient to change all parameters to default
values. Press the ventilation key together with the down key
for 4 seconds. The display indicates a successful reset by
blinking 4 times.
Fig. 8 Auxiliary Data Indications
Aerosphere World / Midibus