Herunterladen Inhalt Inhalt Diese Seite drucken

Command Description - Test Operation; Test Mode - Spheros Aerosphere World Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Aerosphere World:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Aerosphere World / Midibus

3.3 Command Description - Test Operation

3.3.1 Test Mode

This mode is used to diagnose the system checking the inputs and activating
the outputs.
To access this mode, perform the following the steps:
- Press the keys
+
. The display will indicate - -, asking for entering
the access password. The access password is 14.
- Use the key
for increasing the first digit and key
second digit until the correct password is shown on the display.
- Press
to confirm. In case the typed password is incorrect, the panel
will return to indicate the vehicle internal temperature. After verifying the
password, the panel will indicate
- Press
for alternating between the inputs and the outputs.
- By pressing
, the panel will indicate
an input or an output. When it is an input
will show the input status. If it is blinking the input is off, otherwise it is on.
- When you select an output
, press
ventilation LED speed 2 will be on indicating the output is on.
- Press
or
for alternating between other inputs or outputs. When
you alternate the output function, the previous function will be turned off.
- To exit a mode selected input or output and moving to another, press
and by a second press leave the test mode.
The function
allows the A/C system to operate without considering
internal temperature. This function is used when it is necessary to turn on the
A/C for testing and the temperature inside the bus is not enough to allow the
A/C to work. All other protections are enabled in this mode.
36
for decreasing the
,so that all inputs may be tested.
or
, depending whether it is
, the ventilation LED speed 2
for turning it on and/or off. The
Input Description
LED on
Pressure switches
Both pressure
input
switches are OK
(closed)
Ice sensor -
Ice sensor OK.
freezing of
evaporator coil
input
Heating system
Heating board
enabled -input
GL-W002
indicating the
available,
heating system is
enabled and
installed.
operating
Fig. 6 Test Operation Input Readings
Output
Description
Turns on blowers at low speed
Turns on blowers at medium speed
Turns on blowers at high speed
Opens air flap
Turns on fans (condenser motors)
Turns on water pump
Opens heating valve (30 %) (in case there is heating)
Opens heating valve (65 %) (in case there is heating)
Opens heating valve (99 %) (in case there is heating
Gas charge function, allows refrigeration to take place,
independently of the control conditions
Fig. 7 Test Operation Output Readings
LED blinking
One or both pressure
switches in fail status.
Check connections and
pressure switches.
Ice sensor indicates that the
system is frozen. Check ice
sensor and connections.
Heating board (GL-W002)
not installed.

Werbung