Turning on the Appliance
Plug in the mains plug of the appliance.
NT 611 Eco KF
A
B
C
A Switch on button
B Switch off button/test key
C Circuit breaker
D Red indicator lamp
Press the switch on button (NT 611
MWF: the red indicator lamp is ON).
The protection switch is now ready for
operation.
Press the switch off button/test button
of the protection switch (NT 611 MWF:
Indicator lamp goes off). The protection
switch shuts off.
Press the switch on button (NT 611
MWF: the red indicator lamp is ON).
The protection switch is now ready for
operation.
Switch on the appliance at the main
switch.
Continuously dispose of large volumes
of liquid: Switch on the disposal pump.
Disposal or cleaning operation
Continuously dispose of liquids or
clean.
Turn off the appliance
Shut off the disposal pump if necessary.
Switch off the appliance at the main
switch.
Press the switch off button/test button
of the protection switch (NT 611 MWF:
Indicator lamp goes off). The protection
switch shuts off.
Unplug the mains plug of the appliance.
NT 611
MWF
D
I
ON
A
O
TEST
B
C
After each operation
Empty the container.
Vacuum and wipe the appliance inside
and outside with a damp cloth.
Storing the Appliance
Wrap the mains connection cable
around the hooks on the slider.
Wind the suction hose around the slid-
ing bow.
Place the appliance in a dry room and
secure it from unauthorized use.
CAUTION
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
Hold the appliance at the handle and at
the suction pipe to transport it.
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
CAUTION
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.
Care and maintenance
DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Replacing the coarse dirt filter/flat-
fold filter or the exhaust filter
Open filter door.
Replace the coarse dirt filter/flat-fold fil-
ter or the exhaust filter.
Close the filter door, it must lock into
place.
Cleaning the floater
Release and remove the suction head.
Clean the floater with a moist cloth.
Insert and lock the suction head.
– 4
EN
Transport
Storage
17