4.4

Troubleshooting

Fault
Appliance does not
start.
The appliance switch-
es off
during operation
.
Tab. 3: Error diagnosis
4.5

Cleaning and maintenance by qualified persons

Maintenance work that is not listed in Chapters 4.2 - 4.3 may only be carried out by the
ROWI Service Centre (see Chapter 5). In the case of maintenance work within the first 24
months that has not been carried out by persons or companies authorized by ROWI, all
warranty claims shall become null and void.
Possible cause(s)
No power or voltage too
low.
The appliance is not
switched on.
The thermostat is set too low
The temperature set at the
thermostat is above
the room temperature.
The thermal overload switch
has triggered. The appliance
has exceeded the maximum
permissible temperature.
The anti-tipping device has
triggered. The appliance is
tilted at too great an angle
31/40
Remedy
Make sure that the connector is
plugged into the socket. Check
the power supply voltage.
Press the heating level switch to
position "I" or "II".
Increase the
thermostat temperature.
Increase the
thermostat temperature.
Switch off the appliance by
pressing the heating level switch
into the "OFF" position and pull
the plug out of the socket. Allow
the appliance to cool down
for several minutes. Remedy
the cause of the overheating
before restarting the appliance.
Return the appliance to an
upright position and make sure
it is secured against tipping over.