transportation to prevent transport damage.
4.
Cleaning and Maintenance
4.1
Safety measures
P Always pull the mains plug out of the socket before servicing the appliance.
P Only begin the maintenance or repair work once the appliance has cooled down.
4.2
Cleaning
The appliance should be covered after each use to prevent contamination by impurities.
Do not cover the appliance until it has fully cooled down.
If the appliance has nevertheless become dirty, observe the following notes during cleaning:
P Always clean the appliance while cool.
P Pull out mains plug before any work.
P Only clean the appliance with a dry, soft cloth. Never use sharp and/or abrasive
cleaning agents.
4.3
Maintenance
Note that only original parts may be used for repair and maintenance work. Contact the
ROWI Service Centre if need be (see Chapter 5).
4.4
Troubleshooting
The appliance does
Fault
not start.
No power or voltage too
Possible cause(s)
low.
The appliance is not swit-
ched on.
The room temperature is
above the set temperature.
33/40
Make sure the plug is plugged
Remedy
into the socket. Check the power
supply voltage.
Move the main switch to position
"I" and/or press the Stand-By
button.
Increase your desired temperature
GB