5. Maintenance

Always turn off the power before performing maintenance procedures. All the service
procedures below are to be executed with the unit unplugged. Perform before each use or as
needed.
INSPECT ELECTRICAL SYSTEM: Inspect the electrical cord for damage at regular intervals.
Periodically, remove the housing and inspect internal wiring for bare wires, insecure fasteners,
and discoloration. Remove and repair any damaged wiring as needed. Failure to do so may
lead to electrical shock or a fire hazard.
CLEAN AIR INTAKES: Clean off any accumulated lint or other materials from the air inlet side-
screens. A buildup will reduce the airflow and may cause the motor to overheat and become a
fire hazard.
CLEAN EXTERIOR: Clean the housing with mild detergent and water. Bring back the original
shine with a vinyl cleaner and polish like those used on automobile plastics.
EXTERIOR INSPECTION: Evaluate exterior components and make sure they are properly
installed. Listen to the unit for abnormal sounds. Repair or replace components as needed.
DO NOT WET MOTOR OR WIRING: To prevent damage to electrical components, do not use
a duct or pressure washer to clean a blower. If electrical components do become wet, dry them
immediately.

6. Troubleshooting

WARNING: Execute all the service procedures below only with power turned off, i.e. unplugged.
PROBLEM
Motor won't run
Motor runs but wheel turns
erratically or scrapes
Unit vibrates excessively
"FS" or Field Solutions can be handled by the technician in the field | "AST" or Authorized HEYLO-Service
technician.
Questions? Please call us:
Your HEYLO-After Sales Service:
Phone. +49 (0) 42 02 – 97 55 15
Fax
+49 (0) 42 02 – 97 55 97
Email service@heylo.de
CAUSE
No power to machine
Switch not turned on
Blower wheel jammed
Intake or exhaust blocked
Switch is broken
Loose wiring
Severe jolt has caused motor
mount to bend and wheel to rub
Severe jolt caused motor to slip
out of mount and wheel to rub
Accumulation of soil on wheel
Blower wheel has lost balance
Blower wheel has been bent
Bent motor shaft
7
See
above SOLUTION
FS
Plug in the unit; check circuit breaker or fuse
FS
Turn on the switch
FS
Remove material jamming wheel
FS
Turn machine off and allow to cool, then
remove blockage
AST
Call distributor or HEYLO for replacement
switch
AST
Check wiring and tighten as needed
AST
Remove motor from housing, then
replace or repair bent motor mount
AST
Remove motor from housing, then
install motor into mount correctly
FS
Clean blower wheel
AST
Balance or replace blower wheel
AST
Replace blower wheel
AST
Replace motor