6. Maintenance / repair

CAUTION: Remove the mains plug before maintenance and repair.
Inspektion of the electric system: Check the power cord for damage in regular intervals. Remove
the housing in regular intervals and check the internal wiring for bare wires, loose fasteners and
discoloration. If and when necessary remove and repair the damaged cable.
Clean air inlet: Lint or other dirt which has collected at the air let has to be removed. Use vacuum or
pressurised air to remove lint and dust from the impeller, motor and side covers.
Clean housing: Clean the housing with a mild detergent and water. Use a vinyl cleaner and polish,
such as HEYLO POWER Clean plastic cleaner, to restore the original glossiness.
Checking the outer side: Check the external components and make sure that have been installed
correctly. Listen for unusual noises.
Motor and wiring must remain dry: In order not to damage the electrical component parts, the
TurboVent 2000 must not be cleaned with a water hose or pressurised washer. If electrical
components get wet nonetheless, they have to be dried immediately.
In order to clean the unit thoroughly, it can be disassembled as follows:
First of all remove the four screws on the upper side (1), then turn the unit over (2) and remove the six
screws on the bottom side (3). Now, the control cabinet including air mover module can be pulled out
at the bottom (4).
(3) Six screws - lower side
(2) Turn unit over.
(4) Remove the air
mover from the
(1) Four screws - upper side
bottom
EN
13

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Turbovent 2000Turbovent 2000 pro1 110 818

Inhaltsverzeichnis