Verfügbare Sprachen

Verfügbare Sprachen

5. Socket of the unit: Another electrical device can be connected to the socket (D). Please note that
1,000 W or up to 6 A can be connected maximum.
6. Micro fuse: The micro fuse for the socket (D) is located in the fuse holder (E). The fuse used is a
delay-action fuse of 6.3 A.
7. Hour meter: The hour meter (F) indicates the operating hours which may be used for
documentation
(please also observe the energy meter as optional accessory).

6. Use / field of application

The main use of FT 1000 is dust-intensive work at various locations. Here the unit is used for industrial
safety and health protection, ensures the refurbishment targets and increases the efficiency of work.
By air filtration, harmless ambient air is ensured. This is used for the protection of the employee, and
at the same time increases the work performance. Unaffected areas and residents are protected
against detrimental particles from spreading. By sealing off and by generating negative pressure in the
refurbishment area, the success of micro-cleaning in the removal of contaminants is considerably
increased.
ATTENTION: Like all negative pressure units, FT 1000 must be operated only with the corresponding
expertise when dealing with contaminants. The local trade association will inform you about the
required proof of expertise.
ATTENTION: FT 1000 must not be used in explosive areas.
Design: If FT 1000 is used in areas, in which people are employed, the professional association of the
building industry (BG-Bau in Germany) requires a 15-fold air exchange. In order to ensure maximum
performance of FT 1000 and to achieve a correct display of the filters used, the air cleaner has to be
operated at maximum fan stage. If suction or exhaust hoses are used, all hose connections have to be
fitted with hoses (exhaust air two hoses of 205 mm each, and on the suction side three hoses of 205
mm - accessories see chapter (11)).
Circulating air operation: The FT 1000 must be set up in the middle of the area concerned. The
suspended matter stirred up during work and/or use of the room is collected by the continuous air
exchange of the unit and is found in the filter. In this case an air hose should be placed on the air
outlet side or on the suction side in such a way that a ventilation is ensured by the entire area.
Collection at the source Particles should be collected as close as possible to the point of origin.
Basically, quick-running tools should be fitted with dust extraction by means of safety vacuum cleaner.
In order to collect additional free dust, the FT 1000 can be provided with air hoses. These should be
placed as close as possible to the source. This minimises the spread of dust in the room air.
(optionally a holder is offered as an accessory).