10. Maintenance / fault finding

WARNING: Danger of electric shock !
The unit has to be disconnected from the mains before maintenance work is carried out. Electrical
components must not be cleaned with a water hose or pressure washer because water may enter the
electric unit and may cause an electric shock.
When disassembling component parts, please tighten the screws by hand in order to prevent
damage to the thread !
WARNING: Contamination hazard
Always wear the recommended protective equipment and the breathing apparatus when removing or
replacing the filter as well as when cleaning the HEPA filter. Prior to transport, the unit has to be
cleaned completely or as an alternative has to be packed air-tight.

Fault detection and elimination

Problem
The unit is not
operational.
Change filter display is
lit and signal is
sounded.
Impeller is not
operational.
Socket of the unit is
not functional.

11. Optional accessories

Description
Energy meter (assembly kit)
Pre-filter - coarse dust G4 (pack of 3)
Main filter - suspended matter (HEPA) H14
Main filter - fine dust F9
Main filter - activated carbon filter
Dust sheet (cover sheet for closing)
Dust sheet (cover sheet for hose connection socket for suction side)
Cover plate for exhaust opening
Hose connection socket for exhaust opening
Stable foot for hose connection socket - suction side
Air hose diam. 205 mm, length 7.6 m
Telescopic rod - length 3.6 m
Telescopic rod - length 6 m
Dust protection door DCD
Potential cause
The unit has no power.
The unit has not been
switched on.
Main filter is soiled.
Air inlet is blocked.
Fan is blocked.
Micro fuse is defective.
Connect the unit to another socket;
check whether the socket is live.
Switch the switch on.
Change filter; cf. chapter on filter.
Remove kinks in the hose or remove
the hose.
Remove blockage.
Replace micro fuse (6.3 A).
(cf. chapter on operation)
26
Solution
HEYLO Art. No.
1 631 020
1 110 926
1 110 920
1 110 922
1 110 924
1 200 040
1 200 041
1 200 042
1 200 043
1 200 044
1 250 065
1 110 940
1 110 941
1 110 975
EN