3.3 External globe sensor resistance table
-15°C
-10°C
32.937kΩ 25.217kΩ 19.392kΩ
20°C
25°C
5.855kΩ
4.700kΩ
3.4 PinTherm Infra factory settings
• Menu code
• Switching times
• Room temperature
• Calibration
• High/low adjustment
• High/low switching

4.0 Installation

4.1 General

Check for damage after unpacking the PinTherm Infra and external sensors supplied
with it. Check that the type/ model and electrical voltage are correct.
4.2 PinTherm Infra assembly
Decide on an appropriate site for assembling the PinTherm Infra. It is recommended
that the PinTherm Infra be placed at a distance of ±1.5m off the floor.
Check before connecting the cabling that the voltage is switched off. If this is not the
case, the voltage should first be switched off before proceeding any further. If the
voltage is switched off from the appliance to be connected, the appliance's technical
manual/service manual should also be consulted at this juncture.
Connect the PinTherm Infra according to one of the electrical diagrams provided at
the back of this technical manual. To select the correct wiring diagram, you need to
know to which type of appliance you will be connecting the PinTherm Infra. See also
Appendix I for a selection.
4.3 Assembly of external globe sensor
Place the external globe sensor draught-free within view of the appliance at a height of
approx.1.5m off the floor and connect the sensor to the terminals identified for this
purpose in the PinTherm Infra. See table below for the correct cable diameter.
Diameter
Length
0.8mm
2
80 metres
1.0mm
2
100 metres
1.5mm
2
150 metres
-5°C
0°C
15.040kΩ 11.743kΩ
30°C
35°C
3.777kΩ
3.071kΩ
: 1000
: MON, TUE, WED, THUR, FRI 07:30-17:30hrs
SAT, SUN 00:00-00:00 hrs
: Day-time temperature 18°C
Night-time temperature 08°C
: +0.0
: Manual
: PinTherm Infra always starts 1min. at high when
heat is requested
It is recommended that a protected cable be used here.
5°C
10°C
9.241kΩ
40°C
45°C
2.512kΩ
2.066kΩ
15°C
7.330kΩ
50°C
1.709kΩ