Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Care - Kärcher GP 45 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für GP 45:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
The stability of the appliance is warrant-
ed when it is placed onto an even sur-
face.
Operation
Description of the Appliance
1 Power cord with plug
2 Connection G1(33.3mm) Pressure pipe
3 Filling nozzle with pre-filter
4 Connection G1(33.3mm) Suction pipe
5 Drain opening
6 ON/OFF switch
Preparing the Appliance
Please follow the safety instructions before
start-up!
Illustration
 Connect suction and pressure pipes us-
ing Kärcher special accessory G1
(33.3mm).
Note: To pump heavily contaminated
water, e.g. from wells or ponds, we rec-
ommend using an additional prefilter.
(optional: 6.997-344.0)
Illustration
 Unscrew the lid of the filling nozzle and
fill in water till it overflows.
 Screw on the lid on the filling nozzle.
Operation
 Insert the mains plug into the socket.
Illustration
 Tip: Raise the suction hose by approx.
1m to reduce the suction period.
Illustration
 Turn the appliance on via the on/off
switch.
 Wait till the pump sucks in and trans-
ports water uniformly
Warning
The water in the pump heats up if there is
no water supply or the pressure side is
closed and can cause injury if it flows out!
The pump may be operated for maximum 3
minutes in this operating status.
Finish operation
 Rinse the pump after every use if you
use to transport water with additives.
 Turn off the appliance.
 Disconnect the main plug from the
socket.

Maintenance and Care

Danger
Turn off the appliance and remove the
mains plug prior to any care and mainte-
nance work.
Illustration
 Check pre-filter regularly for dirt. If it is
visibly dirty, proceed as follows:
 Unscrew the lid of the filling nozzle.
 Remove the pre-filter and clean it under
flowing water.
 Rinse out dirt residues on the floor of
the filter intake by opening the drain.
 Insert cleaned pre-filter
 Manually screw the lid on to the filling
nozzle and the drain opening and tight-
en it.
The appliance is maintenance-free.
Caution
In order to prevent accidents or injuries,
keep in mind the weight of the appliance
during transport (see Specifications).
When transporting by hand
 Lift appliance by the carrying handle
and carry it.
When transporting in vehicles
 Secure the appliance against shifting
and tipping over.
– 3
EN
Care
Maintenance
Transport
Storage
15