12
12 Device Information
1
Type and order code
2
Design
2.1
Model
2.2
Degree of protection according to EN 60 529
2.3
Installation location
3
Performance data
3.1
Operating temperature limits:
Heating water flow
Cooling, flow
Brine (heat source, heating)
Brine (heat sink, cooling)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of heating water
(flow/return flow)
2
3.3
Heat output / COP
6
3.4
Cooling capacity / COP
3.5
Sound power level
3.6
Sound pressure level at a distance of 10 m
3.7
Heating water flow with an internal pressure differential of m³/h / Pa
3.8
Brine throughput with an internal pressure differential
(heat source) of
3.9
Flow rate of additional heat exchanger
with an internal pressure differential of
3.10 Refrigerant; total filling weight
3.11 Lubricant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Device connections for hot water
4.5
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
5.4
Nominal current
5.5
max. power consumption of compressor protection
(per compressor)
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
1. See output curves
2. The coefficients of performance for parallel hot water preparation are also achieved via additional heat exchangers.
3. This data indicates the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, both the bivalence point and
the regulation should also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow
temperature 55 °C.
4. Operation with 2 compressors
5. Operation with 1 compressor
6. Considerably higher coefficients of performance are achieved by means of cooling operation and waste heat recovery via additional heat exchangers.
7. Note that additional space is required for pipe connections, operation and maintenance.
8. See CE declaration of conformity
9. The heat circulating pump and the heat pump controller must always be ready for operation.
E-8
1
°C
°C
°C
°C
at B0 / W35
K
3
at B-5 / W55
kW / ---
kW / ---
3
at B0 / W55
kW / ---
kW / ---
3
at B0 / W35
kW / ---
kW / ---
3
at B20 / W9
kW / ---
3
at B20 / W7
kW / ---
3
at B20 / W18
kW / ---
kW / ---
3
at B10 / W7
kW / ---
3
at B10 / W18
kW / ---
kW / ---
dB(A)
db(A)
m³/h / Pa
m³/h / Pa
type / kg
type / litres
7
H x W x L mm
Inch
Inch
Inch
kg
V / A
3 4
B0 W35
kW
A
4
B0 W35 / cos ϕ
A / ---
W
9
SI 30TER+
Reversible with additional heat exchanger
Up to 55±1
+7 to +20
-5 to +25
+5 to +30
Monoethylene glycol
22,0 / 2,0
4
11,1 / 2,1
5
24,9 / 2,2
4
5
12,8 / 2,3
4
28,6 / 3,8
5
15,2 / 4,2
4
35,3 / 5,3
5
18,2 / 6,1
4
44,6 / 6,2
5
23,6 / 7,5
21,0 / 8,6
5
46,7 / 7,4
4
5
25,4 / 9,5
4,7 / 2200
6,7 / 5300
4,0 / 20000
R404A / 8,1
Polyolester / 3,7
1660 x 1000 x 775
G 1 1/2" internal/external
G 2" internal/external
G 1" internal/external
400 / 20
13,59 / 0,8
IP 21
Indoors
25%
5
62
46
385
7,53
26
70
8
Yes
2
Internal