4. Technical information:
- Salzburg C
Minimum distances to
combustible materials
CO-content of flue gas @
13%O
2
Flue gas temperature
Thermal output
Thermal storage
capacity
Energy efficiency
Nominal heat output
during discharge period
(100%-25%)
Surface temperature
Chimney draft
Length of wood logs
Weight
Load size (kg)
Max nr. loads
Loading interval
Nr. burning cycles per 24
hours

5. Before Installing a new fireplace

Several European countries have local
regulations for installation of fireplaces, which change
regularly. It is the responsibility of the client that these
regulations are complied with in the country/region
where the fireplace is installed.
Nordpeis AS is not
responsible for incorrect installation.
Important to check
(please note that this list is not exhaustive):
• distance from firebox to combustible/flammable
materials
• insulation materials/requirements between
fireplace surround and back wall
• size of floor plates in front of fireplace if required
• flue connection between firebox and chimney
• insulation requirements if flue passes through a
flammable wall
Chimney Draft
Compared to older models, the clean burning fireplaces
of today put significantly higher demands on the
22
Back
50mm
Side
100mm
Ceiling
550mm
0,1%
140 °C
55,6 kWh
100% after 4,9 hrs
50% after 14,1 hrs
25% after 21,7 hrs
84,0%
3,6 kW
90-140 °C
12 Pa
350 mm
ca. 930 kg
3,0 kg
5
1 / hour
1
chimney. Even the best fireplace will not work properly
if the chimney does not have the right dimensions or
is not in good working order. The draught is mainly
controlled by gas temperature, outside temperature, air
supply as well as the height and inner diameter of the
chimney. The diameter of the chimney should never
be less than that of the flue/chimney collar. At nominal
effect there should be a negative pressure of 12 to 25
Pascal.
The draft increases when:
• The chimney becomes warmer than the outside air
• The active length of the chimney over the hearth
increases
• Good air supply to the combustion
It can be difficult to obtain the right draught conditions
in case the chimney is too large relative to the fireplace,
as the chimney does not heat up well enough. In
such cases you may want to contact professional for
evaluation of possible measures. Draught that is too
strong can be controlled with a damper. If necessary,
contact a chimney sweeper. The product is type
tested and should be connected to a chimney that is
dimensioned for the smoke gas temperature indicated
in the CE declaration. When necessary, contact a
professional in advance
Attention! It is recommended to use a qualified
professional when installing a new fireplace.
Shared flue gas system
Appliance can be connected to shared flue gas pipe
sytem.
Warning! In case of the appliance connected to
shared flue gas pipe system - the Self Closing
Door system must be operational. See FIG 62
Air supply (=mm AIR)
A set for fresh air supply is available as an accessory.
This will ensure that the air supply to the combustion
chamber is less affected by ventilation systems, kitchen
fans and other factors which can create a down-draught
in the room. In all new constructions, we strongly
recommend the product is designed and prepared
for direct supply of outside air. In older houses also,
the use of fresh air supply set is also recommended.
Insufficient air supply can cause poor draught and
thereby low combustion efficiency and the problems this
entails: soot stains on the glass, inefficient utilisation of
the wood and a soot deposits in the chimney.
Warning! Keep the air intakes, supplying
combustion air, free from blockage.
Warrning! Extractor fans when operating
in the same room or space as the appliance
may cause problem.
GB