LAW 6IMR - LAW 14ITR
13 Device information
1
Type and order code
2
Design
Heat source
2.1
Model
2.2
Controller
2.3
Thermal energy metering
2.4
Installation location
2.5
Performance level
3
Operating limits
3.1
Heating water flow / return
3.2
Cooling water flow
3.3
Air (heating)
3.4
Air (cooling)
4
Flow / sound
4.1
Heating water flow / internal pressure differential
in accordance with EN 14511
free compression
Minimum heating water flow
free compression
4.2
Noise-power level in accordance
1
with EN 12102 outdoors
4.3
Sound pressure level in 10 m distance outdoors
4.4
Noise-power level in accordance
with EN 12102 indoors
4.5
Sound pressure level in 1 m distance indoors
4.6
Air flow
5
Dimensions, weight and filling quantities
3
5.1
Device dimensions
5.2
Weight of the transportable unit(s)
incl. packaging internal / external
5.3
Device connections for heating
5.4
Refrigerant; total filling weight
5.5
Lubricant; total filling quantity
5.6
Volume of heating water in the outdoor componentLitres
5.7
Buffer tank
Nominal volume
Permissible operating temperature°C
Max. operating overpressure
Electrical pipe heater
Immersion heater (optional)
5.8
Domestic hot water cylinder
Usable capacity
Heat exchanger area
Permissible operating temperature°C
Max. operating pressure
Immersion heater
5.9
Start-to-leak pressure, safety valve bar
EN-18
°C
°C
°C
°C
m³/h / Pa
Pa
m³/h
Pa
dB(A)
2 1
dB(A)
dB(A)
dB(A)
m³/h / Pa
internal
H x W x D mm
external
H x W x D mm
kg
inches
type/kg
type/litres
in litres
bar
kW
kW
in litres
m²
bar
kW
452162.66.04 · FD 9502
LAW 6IMR
LAW 9IMR
Air
Split reversible
Split reversible
WPM Econ5Plus inte-
WPM Econ5Plus inte-
grated
NO
Indoors / outdoors
Indoors / outdoors
Variable
up to 55 / from 20
up to 55 / from 20
7 to 25
-20 to +30
-20 to +30
+10 to +43
+10 to +43
1,6 / 20000
1,6 / 20000
38800
0,75 / 8500
0,75 / 8500
68500
63
32
42
35
3600
1920 x 740 x 950
1920 x 740 x 950
834 x 950 x 330
834 x 950 x 330
215 / 69
G 1 1/4"
R410A / 1.9
R410A / 1.9
Polyvinyl ether (PVE) / 0.9 Polyvinyl ether (PVE) / 0.9 Polyvinyl ether (PVE) / 1.3
0
100
85
3,0
4
2, 4 or 6
2, 4 or 6
up to 6
277
3,15
95
10,0
1,5
2,5
LAW 14ITR
Air
Air
Split reversible
WPM Econ5Plus inte-
grated
grated
No
No
Indoors / outdoors
Variable
Variable
up to 55 / from 20
7 to 25
7 to 25
-20 to +30
+10 to +43
2,4 / 30400
38800
29600
0,9 / 10000
68500
77300
63
67
32
36
42
42
35
35
3600
3600
1920 x 740 x 950
1380 x 950 x 330
215 / 69
222 / 116
G 1 1/4"
G 1 1/4"
R410A / 2.98
0
0
100
100
85
85
3,0
3,0
4
4
2, 4 or 6
up to 6
up to 6
277
277
3,15
3,15
95
95
10,0
10,0
1,5
1,5
2,5
2,5
www.dimplex.de