10. INSTALLATION

WARNING!
Refer to the Safety chapters.
10.1 Building Under
WARNING!
Only a qualified and competent
person must do the installation of
the appliance. If you do not con-
tact a qualified or competent per-
son, the guarantee becomes inva-
lid if there is damage.
• Before you install the appliance, fit it
with the applicable hob from the table.
Type
EHA6040
EHA6046
10.2 Electrical connection with
the hob
The hob connection socket is at the top
of the oven cabinet. The hob has connec-
tion leads for the cooking zones and the
ground cable. The leads have plug-in
connectors. To connect the hob to the
oven, plug the connectors into the correct
oven sockets. The design of the plugs
and sockets prevents incorrect connec-
tions.
573
Maximum power
6500 W
7600 W
548
558
594
5
600

10.3 Electrical installation

WARNING!
Only a qualified person must do
the electrical installation.
The manufacturer is not responsi-
ble if you do not follow safety pre-
cautions from the chapter "Safety
information".
This appliance is supplied without a main
plug or a main cable.
20
10.4 Cable
Cable types applicable for installation or
replacement: H07 RN-F, H05 RN-F, H05
RRF, H05 VV-F, H05 V2V2-F (T90), H05
589
BB-F.
For the section of the cable refer to the
total power on the rating plate.
10.5 Connecting the terminal
board
The appliance has a six-pole terminal
board. The jumpers (bridges) are set for
operation on a 400 V three-phase with a
neutral wire.